• +49 2372 901 25 40
< Back
High-Voltage AC

High-voltage AC with dU/dt analysis.

What does dU/dt mean?

This technology enables the rapid detection of very small discharge currents – even if full discharge has not yet occurred.

This technology is e.g. ideal for laboratory tests on winding goods such as hairpins. The winding wires are often subjected to extreme mechanical stress for shaping. This could cause cracks in the insulating lacquer. To test the quality we supply high-voltage test equipment with the possibility of testing in a ball or water bath. The high-voltage test is usually carried out with continuously increasing test voltage until the desired maximum test voltage is reached. As soon as the first signs of insulation weakness appear, this is detected by the test device and the high voltage is switched off. The dU/dt evaluation is ideally suited for this purpose.

The oscillogram shows the moment when the voltage curve is no longer sinusoidal. This is caused by an insulation weakness in the test object. The dU/dt evaluation detects this and switches off the high voltage.

YouTube

Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube.
Mehr erfahren

Video laden

By the way, this type of testing in a ball bath with very small metal balls and even better in a water bath is also used on insulating gloves or on power tools insulated with plastic such as VDE screwdrivers. We supply not only the high-voltage test device, but also the entire test equipment including the water bath or ball bath as well as the necessary test cover for inevitable contact protection.

With us you get everything from one source. For your advantage, SCHLEICH develops, designs and manufactures everything in our factory in Hemer.


GLP2-BASIC

Protective conductor, insulation, high voltage, leakage current and function tester
  • insulation Resistance testers – IR
  • high voltage testers AC/DC
  • “All in one” testers
  • safety & function testers
  • app. 40 device variants – combined from up to 21 test methods
  • PLe, SIL3, Kat4 safety circuit (depending on device variant and degree of risk)
  • network
  • protocol & label printing
  • scanner …
  • Technology Package for even more ergonomics
  • table-top unit or 19″ rack mounting

read more

GLP2-MODULAR

Combination tester with up to 25 test methods
  • “All in one”
  • safety testers
  • safety & function testers
  • modular combination of more than 25 test methods possible
  • up to 250 test connections
  • large switch matrix modules for all kind test methods
  • PLe, SIL3, Kat4 Safety circuit (depending on device variant and degree of risk)
  • network
  • protocol & label printing
  • scanner …
  • Technology Package for even more ergonomics

read more