• +49 2372 901 25 40

Safety-Light Curtains

Testing without protection against accidental contact

different sizes and variants ⋅ 1-, 2-, 3- or 4-sided accessible and monitored ⋅ for large or bulky test objects ⋅ marking of the approved test area …

Product consultant

You need a personal product advice?
Please use our direct contact:
+49 2372 901 25 40
Email request

Key-Facts

  • Ergonomic, no mechanical obstruction
  • no opening and closing necessary
  • quick handling
  • Individual height adjustment to your task
  • Mechanically solid and durable constructions
  • Immediate test abort when the light curtain is interrupted during the test
  • two-channel safety evaluation
  • Optional ESD version
  • Solutions for automatic production lines
  • Solutions for integration into your test project
  • Solutions for the installation of manual contacts
  • Solutions for the installation of automatic contacts

Variants

2 solutions for your testing task.

Please select the desired test method:

List view
Compare

Test cabin PKL-1440-1280-1900

test cover typetest cabin
performance level (PL)reachable up to PLe; dual-channel monitoring
CAD data availableyes, on request
deliveryorder-related manufacturing
Test stationwith safety-light curtain
Number of firmly closed sides3
Number of sides safeguarded by light curtain1
Safety category4
Smalles detection height 14 mm
Evaluation of safety-light curtaincertified evaluation modul

Test table PTL-1370-1190-1970

test cover typesafety light curtain
performance level (PL)reachable up to PLe; dual-channel monitoring
CAD data availableyes, on request
deliveryorder-related manufacturing
Test tablewith light curtain
Number of firmly closed sides1
Number of sides safeguarded by light curtain3
Safety category4
Smallest detection height14 mm
Evaluation of safety-light curtaincertified evaluation module

If you haven’t found the perfect safety-light curtain yet, please do not hesitate to contact us.

We would be pleased to help you find a custom solution:

Product consultant

Product consultant

Are you looking for a personal consultation?

Please contact us directly: +49 2372 901 25 40

Or simply send us your questions via e-mail.

E-mail inquiry

Description

SCHLEICH test stations with safety light curtain are a solid, long-life investment to reduce the operator’s risk. Ergonomics are the main reason of this safety device.

The use of an optoelectronic safety light curtain is less restrictive in terms of handling. It improves productivity – but also somewhat restricts safety. With the appropriate design, it is ensured that when a person falls into the test station, the test object is voltage-free and discharged quickly enough. For this purpose, however, a prescribed safety distance must be maintained around the test object. These are not insignificant and can be between 10-30 cm depending on the application. This can restrict the ergonomics and handling of large or heavy test DUTs.

In addition, mechanical movements must be stopped safely within the shortest possible time. For example, electric motors with freely accessible shafts must stop very quickly before they can be touched. This can also mean that a safety light curtain cannot be used.

Most safety light curtains have a beam distance of 14mm. This makes the light barrier finger-safe. However, it is not possible to reliably identify cables coming out of the test room. Despite various design measures, it is possible that thin cables outside the light curtain are not detectable. This can lead to dangerous voltage transmission to the outside.

These factors may make additional safety measures necessary. However, it could also be that the use of a safety light curtain is excluded.

To protect sensitive electronic DUTs from electrostatic charging and discharging, test stations are optionally made of ESD materials.

For further information please do not hesitate to contact our technical sales under:


print preview

Product comparison

 
 
 
 
test cover type
model range
width x depth x height (inside)
width x depth x height (outside dimensions)
height of floor box
performance level (PL)
rated voltage
LED result lights
warning lights
limit switch
opening angle of the test cover
automatic opening
automatic guard closing
guard locking during the test
industrial socket for test cable
carrying capacity of the base
ESD design
Faraday cage design
pass through of conveyor system
bottom with ball transfer system
table frame
installed on rolling container
Installation in SCHLEICH rolling tables
CAD data available
delivery
 
 
 
Abbildung Einzelprüfhauben Single Test Covers
read more  
Abbildung Doppelprüfhauben Dual Test Covers
read more  
Abbildung Sicherheitslichtvorhang Safety-Light Curtains
read more  
Abbildung Prüfkabinen Test Cabins
read more  
Abbildung Prüffelder Test facilities
read more  
Abbildung Sonderprüfhauben Custom-made test covers
read more  
Abbildung Einzelprüfhauben Abbildung Doppelprüfhauben Abbildung Sicherheitslichtvorhang Abbildung Prüfkabinen Abbildung Prüffelder Abbildung Sonderprüfhauben
Single Test Covers
 
Dual Test Covers
 
Safety-Light Curtains
 
Test Cabins
 
Test facilities
 
Custom-made test covers

various sizes ⋅ ergonomic ⋅ smooth-running ⋅ long service life ⋅ up to Performance Level PLe ⋅ integrated result lights ⋅ automatic opening ⋅ guard locking ⋅ adapter installation …

alternating testing ⋅ various sizes ⋅ ergonomic ⋅ smooth-running ⋅ long service life ⋅ up to Performance Level PLe ⋅ integrated result lights ⋅ with guard locking ⋅ plenty of space for adapter installation …

various sizes ⋅ 1-, 2-, 3- or 4-sided open and monitored ⋅ for large or bulky test objects ⋅ accessible with pallet jack ⋅ marking of the approved test area …

safety door or roller shutter ⋅ up to Performance Level PLe ⋅ ideal for large devices under test ⋅ suitable for pallet trolleys ⋅ sturdy industrial quality ⋅ long service life …

accessible by forklift ⋅ several access doors ⋅ monitoring with safety PLC ⋅ up to performance level PLe ⋅ several emergency stop buttons and warning lights ⋅ robust industrial quality ⋅ long service life …

Individual customer-specific solutions of any kind, application and size

read more   read more   read more   read more   read more   read more  
single test cover double test cover safety light curtain test cabin test facility
model 13-R2
model 10
model 21
model 20
model 1
model 0
model 3
model 12
458 x 600 x 400 mm
800 x 600 x 500 mm
1100 x 600 x 500 mm
1000 x 600 x 500 mm
900 x 600 x 500 mm
800 x 754 x 500 mm
900 x 800 x 645 mm
900 x 730 x 330 mm
700 x 730 x 330 mm
500 x 730 x 330 mm
230 x 350 x 195 mm
688 x 536 x 345 mm
588 x 536 x 345 mm
488 x 536 x 345 mm
385 x 536 x 345 mm
620 x 782 x 515 mm
946 x 837 x 625 mm
1246 x 837 x 625 mm
1146 x 837 x 625 mm
1046 x 837 x 625 mm
946 x 987 x 625 mm
1046 x 987 x 770 mm
946 x 792 x 520 mm
746 x 792 x 520 mm
546 x 792 x 520 mm
265 x 390 x 305 mm
1400 x 617 x 500 mm
1200 x 617 x 500 mm
1000 x 617 x 500 mm
800 x 617 x 500 mm
75 mm
reachable up to PLe; dual-channel monitoring reachable up to PLe; dual-channel monitoring reachable up to PLe; dual-channel monitoring reachable up to PLe; dual-channel monitoring reachable up to PLe; dual-channel monitoring reachable up to PLe; dual-channel monitoring
max. 12 kV AC / 16 kV DC
max. 6 kV AC / 8 kV DC
max. 8 kV AC / 10 kV DC
max. 3 kV AC/DC
max. 6 kV AC / 8 kV DC
max. 8 kV AC / 10 kV DC
various models up to max. 50 kV AC/DC
max. 6 kV AC / 8 kV DC
max. 100 kV
GO / NO GO - integrated in the test area
GO / NO GO - mounted on the test cover
GO / NO GO - integrated in the test area GO / NO GO - at the front
GO / NO GO - integrated in the test area
GO / NO GO - integrated in the test area
optional 2 pieces
2 x CAT IV limit switches, contactless
almost 90° mechanical almost 90° mechanical
not possible
optional
yes
not possible
optional
not possible
optional
optional
not possible
yes
not possible optional
not possible
optional
optional, pneumatic or electric
yes
optional, pneumatic
yes
not possible
optional, pneumatic or electric optional, pneumatic or electric
prepared for 3 pieces
prepared for 4 pieces
prepared for 1 piece
prepared for 2 pieces
15 kg / 33 lbs
150 kg / 330 lbs
25 kg; 50 kg optional / 55 lbs; 110 lbs optional
50 kg / 110 lbs
50 kg; 150 kg optional / 110 lbs; 330 lbs optional
20 kg; 50 kg optional / 44 lbs; 110 lbs optional
15 kg; 50 kg optional / 33 lbs; 110 lbs optional
15 kg; 150 kg optional / 33 lbs; 330 lbs optional
2000 kg / 4400 lbs
optional optional optional
optional optional
not possible
optional, max. 400 mm wide optional, max. 400 mm wide optional, max. 400 mm wide optional, max. 400 mm wide optional, max. 400 mm wide
optional optional optional optional optional
no
optionally with adjustable feet
optionally with castors
with adjustable feet included in delivery
optionally with adjustable feet
optionally with castors
with adjustable feet included in delivery
optionally with castors
not possible
optional
not possible
optional
not possible
optional possible
not possible
yes, on request yes, on request yes, on request yes, on request
on stock
order-related manufacturing
order-related manufacturing order-related manufacturing order-related manufacturing order-related manufacturing
 

SCHLEICH is a leading manufacturer of electrical safety, functional, winding and electric motor testing technology.

SCHLEICH is a world-renowned company that focuses on the development of innovative products in the field of testing technology for electrical products of all kinds.
From A to Z - everywhere SCHLEICH testing technology is in use worldwide. Our customers come from over 50 countries and regions. Everything is developed and produced in Germany.

Quality work - Made in Germany.

2022 - SCHLEICH is awarded for the fifth time as TOP100-Innovator
2016 - SCHLEICH released the first VoltageAnalyzer for measuring the real voltage directly at the winding terminals
2012 - SCHLEICH is awarded as TOP100-Innovator for the first time
2005 - SCHLEICH released the first stator tester with partial discharge test
1995 - SCHLEICH integrates touch-displays into testing devices as a world leader
1990 - SCHLEICH released the first safety and function tester with fully automatic integrated test terminal changeover
1987 - SCHLEICH released the first surge tester with PC-control under DOS and fully automatic integrated test terminal changeover
1985 - SCHLEICH released the first MotorAnalyzer
1982 - SCHLEICH focuses fully on electrical test engineering of electrical products
1952 - SCHLEICH is founded as a motor repair shop

Pioneering spirit, competence, curiosity, brand new technologies and innovations. This is what the 145-strong SCHLEICH team stands for - led by Martin & Jan-Philipp Lahrmann. Father & son. Your guarantors for long-term partnership.

Learn more about us

 

Scripts only