Earth conductor resistance and insulation resistance tester

This Handheld the ideal testing tool for production and mobile use in the workshop as well as on-site at the customer's location. And it comes at a very attractive price.

Typical applications include electrical safety inspections in production and maintenance. Examples include maintenance of medical devices in hospitals or testing the lightning protection on wind turbine blades.

Key Facts:

  • Protective conductor up to 10 A AC
  • Typical test voltage: 6 / 12 V
  • Evaluation criterion: Earth conductor resistance
  • Insulation resistance at 1000 V DC
  • Test current limited to the safety current
  • Evaluation criterion: Insulation resistance
  • Integrated test socket
  • Small, lightweight, and portable
  • Start/stop buttons and test method selection on both sides for left- and right-handed users
  • Large scoreboard
  • Internal data logger for delayed transmission of measurement values to a PC

1 Product Variant

HandHeld

Test Methods » PE · ISO
Device typeEarthing conductor tester
Insulation tester
protective conductor10 A @ 6/12 V
Isolation1 kV / ≤30 MΩ
DesignDesk cabinet
Availabilitywithin 5 business days
Order number 403001
Show all 1 product variant


: The mobile specialist for safety inspections. Compact. Ergonomic. Rugged.

The HandHeld is your go-to tool for performing protective conductor and insulation resistance tests in accordance with industry standards. Thanks to its compact, rugged design, you can perform safety tests not only efficiently in the workshop and on the production floor, but also flexibly and on-site—making it ideal for repair, installation, and service calls at the customer’s location.

Rugged technology for outdoor use

Designed specifically for mobile use, the entire testing system is housed in an extremely robust die-cast aluminum enclosure.

Data storage

Thanks to the built-in test result memory, there is no need to manually record the test results.

The measured values can be transmitted to a PC via the serial interface, where they can be archived and printed.

Test methods

Testing procedure Specifications & Benefits
Protective conductor resistance Test using 10 A AC with precise four-wire measurement. The results can be evaluated based on either the resistance or the voltage drop.
Insulation resistance The measurement can be based either on resistance or current.
Advanced insulation testing The device offers the option of increasing the test voltage to a maximum of 2,500 V DC. This is an interesting alternative to high-voltage testing with alternating current (where 1,800 V AC rms corresponds to approximately 2,500 V DC).

Flexibility in contacting

There are two ways to make contact with the test object:

  1. The integrated test socket: This is where the test object is connected. The tester uses the test probe to manually scan the individual test points one by one.
  2. Alternatively, the protective conductor of the test object can be connected using a test lead with an alligator clip. The tester uses the test probe to manually scan the individual test points one by one.

Special application: Testing lightning conductors on wind turbines

To do this, the PE minimum current monitoring can be disabled, allowing measurements to be taken with a reduced test current. Using a 50-meter-long test lead, resistances up to 15 Ω can be measured using the four-wire method.

Accessories

A wide range of accessories, such as a carrying case and a shoulder strap, make it easier to use on the go and enhance user comfort.

The controls and connections

Standard equipment

Function and Technology

  • Manual testing procedure
  • Built-in test result memory
  • Rear connector for test probe (earth or insulation resistance)
  • Rear connection for a test lead with alligator clips for connecting the test object to the ground (PE).

Communication

  • 1 x RS232 port on the back
  • RS232 for saving test results to a PC using the free SCHLEICH PC software PrintCom 7
  • Printing Test Reports with PrintCom 7

Safety

  • Protective conductor test: low-voltage test voltage 
  • Insulation test: safety-current-limited, non-hazardous test current
  • Special protection against accidental contact is not necessary

The test report with PrintCom

Free PC software for saving and printing test results

PrintCom is a simple and efficient solution for saving test results and printing test reports. Test results can be saved inExcel® and printed.

The PrintCom PC software is included with the tester. The tester has a built-in memory for test results. PrintCom can read this memory after each test or at a later time. PrintCom saves the test results on the PC and allows you to print a test report.

Import, display, and print test results.

Digital logging is a breeze with this software: It quickly transfers test data via the serial interface and displays it in a clear, organized format on your PC. Print the test report directly for your customers or save it as a PDF to help protect the environment.

File format for test results

PrintCom saves your test results ina user-friendlyformat directly in Excel®. Enjoy maximum flexibility when generating reports.

  • The software already includes a wide selection of preconfiguredExcel® test report templates in various layouts.
  • Easy customization: Customize these templates directly inExcel® to meet your needs. For example, add additional information or personalize the test report with your company logo.
  • You can create entirely new test report layouts on your own inExcel® at any time.

Online mode

In online mode, the testing device is continuously connected to a PC, and PrintCom is running. As soon as a new test result is generated after a test, it is immediately transmitted to the PC and stored there. Once all tests are complete, the collected results are saved.

Offline mode

Alternatively, the testing device can temporarily store the test results. This allows you to load and save the test results in PrintCom at a later time.

Network

By configuring the save path accordingly in PrintCom, you can, of course, also saveExcel® files to a network location.

All the facts at a glance

Multifunction tester for PE and insulation

  • Test current up to 10 A AC
  • Electronic test current adjustment with regulated current stability
  • Insulation resistance test up to 1 kV DC
  • Electronic test voltage adjustment with regulated voltage stability
  • Easy to use
  • Start/stop buttons and test method selection on both sides for left- and right-handed users
  • Large scoreboard
  • Automatic comparison with user-defined thresholds
  • Visual and audible alert if the test result is outside the limit
  • Internal data logger for delayed transmission of measurement values to a PC
  • Includes PrintCom for saving and printing test results on a PC
  • Designed for easy transport
  • Small, lightweight, and suitable for carry-on luggage on airplanes
  • Accessories for mobile use, such as carrying straps, outdoor carrying cases, etc.
  • Standard model – in stock
  • Includes a traceable factory calibration certificate

Areas of application

Machinery Directive EN 60204

HandHeld verifying compliance with the Machinery Directive on a piece of equipment.

Lightning Protection Inspection of Wind Turbines

In the field, this rugged tester proves its worth thanks to its optimal comfort and ease of use. It measures the reliable conductivity of the lightning protection system from the tip of the rotor blade to the base of the tower.

Safety inspections in medical facilities

A typical application for testing the protective conductor and insulation on medical devices after repair or maintenance.

Downloads

Do you need personalized product advice?

We are happy to provide you with comprehensive support and advice on all our products and services.
Give us a call or send us an email!

  • Subscribe to the SCHLEICH newsletter

    Our free newsletter—delivered straight to your inbox.

  • Fields marked with * are required.

"*" indicates required fields

Contact Form

Fields marked with * are required.
Accepted file types: pdf, jpg, jpeg, Max. file size: 10 MB.
  • These are only uncompressed JPG/JPEG and PDF files is permitted.
  • The maximum file size is 10 MB.
Privacy Policy*