GLP2-MODULAR
High-voltage testing equipment

Test equipment with high voltage AC up to 100 kV

Multitest testers with high-voltage AC/DC, insulation

GLP2-MODULAR offers you the most comprehensive line of high-voltage test equipment currently available on the market. Whether you need AC, AC with rectification, DC with highly stable output voltage, or a combination of AC and DC in a single “ device .”

The high-voltage test equipment is used to check the electrical insulation capability and dielectric strength (air and creepage distances) of electrical components and assemblies of all kinds.

These testing devices are ideal for quick and easy testing on the production floor or in the lab. Testing can be performed manually using safety guns or automatically run.

We manufacture the “ GLP2-MODULAR ” high-voltage testers based on the SCHLEICH MODULAR CONCEPTS custom according to your specific requirements. Depending on your needs, your application can be housed in a compact desktop device, a 19” rack-mount unit, a 19” container, or a 19” industrial cabinet. The flexibility of the SCHLEICH MODULAR CONCEPTS is evident not only in the housing but also in the number and arrangement of the tester’s connections. With the 19-inch container—and especially with the 19-inch industrial cabinet—the measurement connections can be mounted on all sides of the tester. This allows us to meet all spatial requirements.

Key Facts:

  • High-voltage AC test equipment
  • High-voltage test equipment AC and DC
  • High-voltage DC test equipment
  • Extremely low ripple at high DC voltage
  • Insulation resistances at high DC voltage up to 10 TΩ
  • High voltage with ramps for acceleration and deceleration
  • High voltage with voltage profiles
  • Step voltage measurement
  • quick shutdown at breakdown
  • contact control or cable break monitoring (4-wire system)
  • Minimum current monitoring
  • Long-term measurements over hours, days or weeks
  • High-voltage matrix for switching between different test points
  • Matrix from 1 kV to 50 kV AC
  • Dual-circuit safety inputs, two-hand start
  • Safety circuits with positively driven safety relays
  • VDE 0104 compliant power-on sequence

Operating modes

Flexible test plan creation, test order data entry, result storage, serial number assignment, freely configurable label printing, barcode functions, and many other features leave nothing to be desired. Thanks to various interfaces to the modern IT world, there are virtually no limits to integration into demanding manufacturing processes.

The testing devices can be operated in three modes:

  1. Manual check with no time limit. The system shuts down only when a " excess current" is detected, which is generated, for example, by a " breakdown ."
  2. Testing with programmed timing and various additional monitoring functions.
  3. Insulation Fault Location Using “Burn

There are two types of high-voltage adjustment.

  1. Automatic Voltage Setting
    In automatic mode, the tester automatically sets the voltage to the value specified in the test plan or automatically generates a freely programmable voltage profile.
  2. Manual Voltage Setting
    In manual mode, the voltage is set using the " rotary button " on the front of the device.

provide ffers a wide variety of test guns tailored to your application. Of course, we also carry the appropriate high-voltage cables and connectors in our product line for use with the test equipment in laboratories, automated production lines, or test setups. The safest approach is to conduct the high voltage test inside a test cage. We supply test cages in a wide variety of designs and sizes to suit a broad range of tasks. If our standard test cages do not meet your requirements, we can manufacture specialized custom test cages for you.

high voltage test with voltage profiles

Standard equipment

Function and Technology

  • Large capacitive touch display

  • Clear screen display without sensory overload

  • Microsoft® Windows Operating System

  • High-performance test plan editing

  • Integrated plausibility checks of all parameters

  • Fast, precise measurement technology

  • Enormous configuration options

  • Script editor for maximum flexibility

  • Test plans and test results secure save

  • Storage locally or on the network

  • Monitoring of switching cycles according to Industry 4.0

  • Remote maintenance and remote calibration via remote access
  • Numerous national languages

Communication

  • USB ports on the front and back

  • RS232 and LAN/Ethernet automation interface

  • Digital I/O interface

  • Result outputs for GO and n.GO

  • Interfaces for barcode scanners and label printers

  • CAN bus

 

Optional automation interfaces:

  • EtherCAT
  • PROFIBUS
  • PROFINET
  • and more

safety

  • Starting entrance

  • Dual-circuit safety entrances according to EN50191

  • Design for Performance Level “e”

  • connection For external dual-circuit emergency stop

  • Connections for warning and result lights

  • Safety and Warning Messages

All the facts at a glance

Custom-designed high-voltage test equipment from 1 to 100 kV

  • High-voltage AC test equipment
  • High-voltage test equipment AC and DC
  • High-voltage DC test equipment
  • Extremely low ripple at high DC voltage
  • Insulation resistances at high DC voltage up to 10 TΩ
  • High voltage with ramps for acceleration and deceleration
  • High voltage with voltage profiles
  • Step voltage measurement
  • quick shutdown at breakdown
  • Display of measured values ​​in a graph
  • Three HV modes: Manual, Automatic with timer, and Burn
  • contact control or cable break monitoring (4-wire system)
  • Minimum current monitoring
  • Stress-free contacting with special test guns
  • Zero-voltage switching to protect the device under test
  • Manual high-voltage setting via rotary button
  • Electronic high-voltage control with very fast ramps
  • Long-term measurements over hours, days or weeks
  • Archiving of individual long-term measurements
  • High-voltage matrix for switching between different test points
  • Matrix from 1 kV to 50 kV AC
  • Dual-circuit safety inputs, two-hand start
  • Safety circuits with positively driven safety relays
  • VDE 0104 compliant power-on sequence
  • Includes a traceable factory calibration certificate
  • Includes SCHLEICH.CARE.PREMIUM

Project Examples

High-voltage testing system for rail vehicles

Testing rail vehicles can be literally electrifying. Electrifying because it involves test voltages of up to 80 kV! And, of course, high test currents as well. For insulation tests on rail vehicles, high-power voltage sources are therefore required.

But the design of the high-voltage tester is also rather unusual compared to standard laboratory practice, because who would want to stand right next to an 80-kV system? For this obvious reason—and often due to space constraints—a split-type unit is the ideal design for such applications.

  • high-voltage transformer at 80,000 VAC (rms)
  • Insulation of the transformer with insulating oil
  • Voltage measurement via an integrated high-voltage divider
  • Test current up to 200 mA

Complete solution with high-voltage test chamber

The interior of the test chamber is completely lined with metal walls that are continuously grounded . This reliably shields any high-voltage flashover to the interior wall from the outside and safely diverts it to ground. The high-voltage transformer is also connected to ground on one side.

The door, which is easy to open and close, has a metal lining on the inside and a large glass window for observing the object being tested. A grounded wire mesh is located in front of the glass window for added protection.

When closing, the door presses against circumferential grounded contact tongues to securely seal the gap between the interior and the exterior. For maximum safety , the door is equipped with a 2-channel safety limit switch of Safety Category IV. This allows the test chamber to be connected directly and easily to the test equipment.

High-voltage testing system for rail vehicles

The high-voltage system is mounted directly on a sturdy, mobile cart built-in. Thanks to its large casters, the system can be moved effortlessly—even over obstacles such as cables or hoses on the floor.

Operation is conveniently performed from the front, while the high voltage is output at the rear. With this open operating mode, suitable barriers and comprehensive safety measures are absolutely essential.

Downloads

Do you need personalized product advice?

We'd be happy to provide provide you with comprehensive support and advice on all our products and services.
Give us a call or send us an email!

  • Subscribe to the SCHLEICH newsletter

    Our free newsletter—delivered straight to your inbox.

  • Fields marked with * are required.

"*" indicates required fields

Contact Form

Fields marked with * are required.
Accepted file types: pdf, jpg, jpeg, Max. file size: 10 MB.
  • These are only uncompressed JPG/JPEG and PDF files is permitted.
  • The maximum file size is 10 MB.
Privacy Policy*