GLP1-g Safety and Functional Testers
Stand-alone testers for protective conductor resistance, insulation resistance, and high voltage test
Multifunction testers for universal safety and functional testing
Whether you need a single-function or multifunction device, the GLP1-g offers flexible testing of electrical products in accordance with the latest standards. This tester combines numerous intelligent features, covering all areas of modern electrical safety and functional testing—from production and laboratory use to automation.
The GLP1-g offers a wide variety of test method combinations to meet the diverse requirements of industry and testing laboratories. There are over 50 device variants available, each featuring different combinations of test methods.
Key Facts:
- Single-function and multifunction testers
- Protective conductor testers up to 75 A
- Insulation testers up to 10 kV
- AC High-Voltage Testers up to 50 kV
- DC High-Voltage Testers up to 10 kV
- function test up to 5 A
- Manual checks
- Fully and partially automated testing
- Fully automatic test method switching
- Short delivery time or in stock
53 Product Variants
Show all 53 product variantsThe GLP1-g – innovative, versatile, and compact

The GLP1-g's robust and compact design ensures high performance and reliability. To match the tester's capabilities, we integrate the technology into a rugged industrial enclosure th specialized ly developed for this class of devices.
For optimal performance, the viewing angle can be easily adjusted to suit individual work situations. Whether sitting or standing, whether short or tall—the viewing height of the display, the operation of the testing device, and the “ connection ” of the test object are always optimally tailored to the specific operator.
The integration of up to 9 test methods into a compact device is unique in this class. The GLP1-g provides a clear and well-organized display of the tests. The intuitive user interface greatly simplifies day-to-day testing. The easy-to-read touchscreen is seamlessly integrated into the front built-in and offers the functionality you’ve come to expect from a modern testing device.
The housing options are very flexible. The front panel features the base with the test socket, as well as sockets for test probes and high-voltage test guns.
For integration into automated test systems or for expansion, additional connectors—such as the 10-pin test connector—can be added to the rear of the device. This makes it easy to connect universal junction boxes, test enclosures, or cables for automation.
Depending on the configuration, the device dimensions are based on a rugged and compact ½ 19″ or 19″ enclosure.


The ports on the back of the device
Standard equipment
Function and Technology
- Manual test sequence
- Semi-automatic test sequence
- Fully automatic test sequence
- Built-in test plan memory for up to 1,000 settings
- Built-in " test result memory " for up to 790 test steps
- Multilingual user interface – flexible and suitable for global use
Communication
- RS232, USB, and LAN automation interfaces for remote control
- RS232, USB, or LAN for " save " of the test results on a PC using the free SCHLEICH PC software PrintCom
- Printing Test Reports with PrintCom
- Communication via LabVIEW drivers
- Remote control via I/O
- 6 open 24 V inputs/control inputs
- 7 available 24 V outputs/status outputs
- connection for barcode/Data Matrix scanners
- USB service port on the front panel
safety
- 2-channel safety inputs in accordance with EN 50191
- Warning light traffic signal connection
- Scoreboard connection
- connection for test cover, foot-switch, external safety switches, door contacts, light curtains, emergency stop buttons, two-hand controls, etc.
- key switch for devices without a safety current limit
- Safety and Warning Messages
- Built-in validity checks
- Integrated, explanatory help texts for each input field
The testing software
With the GLP1-g, you always have all relevant measurement values at a glance. The clear display of the test results enables structured—and therefore efficient—work and simplifies the subsequent analysis of individual tests.
Display Options
Depending on the device model, there are generally two different display modes during the test:

For testers with only one " test method ," the results are displayed using a bar graph and a numeric display.

Test equipment that combines two or more test methods displays a test plan— result —showing the individual test steps.
protective conductor resistance

The test report displays the measured values, the Test current , and the test duration.
insulation resistance

The data is displayed as a bar graph with additional tolerance ranges and as numerical values. The display shows the insulation resistance, the TEST VOLTAGE , and the test duration.
High voltage


The results are displayed as a bar graph with additional tolerance ranges and as numerical values. The following values are displayed: the TEST VOLTAGE, the Test current , and the test duration.

Alternatively, the display can be switched to an analog view. In some applications, this is advantageous because it improves readability.
Multifunction device

On a multifunction tester, all test steps are listed one below the other. During the test, a yellow horizontal bar indicates the active test step . Tests that have already been completed are marked either in green for GO or in red for n.GO . For high-voltage tests with a ramp, the ramp profile is also displayed graphically.

Once the test is complete, the overall result is shown on the display as a green or red box. In addition, the individual results of each test step are listed.
The menu – simple and intuitive
The various operating settings are simple and clearly organized: You can load and edit test plans, customize test parameters , or change the device's default settings. Operating the device via the touchscreen is straightforward.
A built-in help function provides a detailed explanation for every test parameters and setting value. Thanks to the automatic validity check performed after each entry, you can always be certain that every test parameters or setting value you enter falls within the device’s technical limits. This ensures error-free and reliable test sequence.

To access the menu, click the "Menu" button.

Select the desired activity from the main menu. You can load and edit inspection plans, set up " test parameters ," configure basic settings, or view statistics.

Here, you can name, save, load, or delete test plans. Click the "Parameters" button to access the parameter selection.

Use the red frame to select the parameter you want to edit or change. To edit the parameter, click the "Edit" button.
automatic test method switch-over , and Mechatronics
SCHLEICH's testing technology has proven itself countless times in daily use. It is among the most reliable products on the market and offers outstanding performance and accuracy. The goal must be to conduct tests quickly and efficiently. Only this ensures high utility value.
To save time, all connections on the test object are connected via the test jack or appropriate test leads. The tester then performs the tests fully automatically between all connections without the need for time-consuming reconnection of leads. The typical device under test for the GLP1-g has a power connection with L, N, and PE.
The " automatic test method switch-over " automatically switches between the various test methods on the connectors and the " test tip ." The appropriate " switch-over "built-in is selected based on the type and scope of the test device. This ensures quick and automatic switching between the different test methods.
Because voltage differences between test methods can be very high, safety ( safety ) is the top priority when switching circuits. A 12-volt protective earth resistance test must be connected to the device under test just as reliably as a 6,000-volt high voltage test —to protect your test object and, of course, to protect the operator. There can be no compromises here! That is why we use only proven, high-quality components—either from our own production or from renowned German manufacturers—for switching circuits and matrices.

Test Methods

protective earth resistance test
The protective conductor is tested using an electronically controlled, constant- Test current. Based on the voltage drop across the protective earth conductor and the current flowing through it, the tester calculates the protective conductor resistance. This value must not exceed the maximum resistance specified in the standards. Using a test tip (to be ordered separately), the operator scans the protective conductor connections to be tested one after another at the device under test . The test is performed between the PE contact in the test outlet and the test tip.

Insulation Resistance Test
insulation test is performed using an electronically controlled, constant TEST VOLTAGE. The tester calculates the insulation resistance based on the voltage drop across the insulation and the current flowing through it. This value must not fall below the minimum resistance specified in the standards. insulation resistance can be measured both between all electrical conductors (Class I devices) and between the electrical conductors and insulated housing parts (Class II devices). The operator uses the test tip to scan the housing parts to be tested one after another. At the end of the test, the test object is always discharge .

high voltage test DC
high voltage test is performed using an electronically controlled, constant high voltage. During the test, the Test current must not exceed a specified maximum value. If the current rises above the maximum value, the test is automatically Cancelled. At the end of the test, the test object is always discharge .

high voltage test AC
insulation test is performed using an electronically controlled, constant high voltage. During the test, the Test current must not exceed a specified maximum value. If the current exceeds the maximum value, the test is automatically Cancelled. At the end of the test, the test object is always discharge .

function test
function test s of your test object are performed at operating voltage based on the current consumption, the power factor (cos), and/or the power consumption of the test object. Target values and ± tolerances can be specified for each measured quantity. If the electrical measured value falls within the tolerance, the test result GO (GO). The TEST VOLTAGE for the function test is generated electronically by the test device.
test protocol s with PrintCom
Free PC software for save ing and printing test results
PrintCom is the simple and efficient solution for printing " test results " to " save " and test reports. The " test results " can be saved inExcel®or, alternatively, inOpenOffice® Calc and then printed.
The PrintCom PC software is included with the tester. The tester features a built-in test result memory. PrintCom can read this data after each test or at a later time. PrintCom saves the test results on the PC and allows you to print a test report.
test results read, display, and print.
Digital logging is a breeze with this software: It quickly transfers the test data via the serial interface and displays it in a clearly structured format on your PC. Print the test protocol directly for your customers or save it as a PDF to help protect the environment.
Storage format of the test results
PrintCom saves your test results in a user-friendly manner directly inExcel® format. Take advantage of maximum flexibility when creating reports.
- The software already includes a wide selection of preconfiguredExcel® test report templates in various layouts.
- Easy customization: Customize these templates directly inExcel® to meet your needs. For example, add additional information or customize the test protocol custom with your company logo.
- You can create entirely new " test protocol" layouts on your own inExcel® at any time.
Online mode
In online mode, the testing device is continuously connected to a PC, and PrintCom is running. As soon as a new " test result " is generated after a test, it is immediately transferred to the PC and stored there. Once all tests are complete, the collected results are saved.
Offline mode
Alternatively, the testing device can temporarily store the test results . This makes it possible to load the test results into PrintCom at a later time and access save.
Network
By configuring the storage path accordingly in PrintCom, theExcel® files can, of course, also be accessed on the network save.
PC Software – System Requirements

All the facts at a glance
Single-test units for HV AC/DC, PE, or insulation
Combination testers with up to 9 test methods and integrated test method switching


- ALL-IN-1 Multifunction Testers
- The world's smallest test device with this power density
- All test methods are controlled fully electronically and wear-free
- Automatic " switch-over " between test methods and test connections
- Fully automatic, semi-automatic, or manual test sequence
- Fully automatic or manual high-voltage adjustment via rotary wheel
- Desktop or mobile device in the caddy
- 19-inch rack mount for automation
- Compliant with EN 50191 (Installation and Operation of Electrical Test Systems)
- 2-channel safety inputs
- PL e, SIL 3, Cat. 4 safety circuit (depending on device model and hazard level)
- Safety circuits with positively driven safety relays
- High process reliability
- Operated via an intuitive touchscreen
- Integrated Test Plan and test result memory
- IncludesPrintComfor save and printing from test results on a PC
- Remote-controlled for automation
- SCPI Communication
- LabVIEW driver
- Benchtop or 19-inch rack-mount device for automation
- Global voltage range: 100–240 V AC, 50/60 Hz
- Standard model/standard version in stock or with very short lead time
- Includes a traceable factory calibration certificate
- Includes SCHLEICH.CARE.PREMIUM
Areas of application
The GLP1-g is designed for a wide range of applications and can be precisely tailored to your needs through a variety of configurable options. You’ll receive a tester that’s perfectly suited to your daily work.
Manual inspection | Inspection station – Repair station – Laboratory
The unique manual mode allows you to apply all test methods integrated into the tester directly and manually as needed. No prior configuration of the tests is required. Simply select the desired test method and start your test. Similar to a multimeter, the software always displays the current measurement values. This allows you to evaluate your test object immediately and in full detail.
Long-term analyses spanning hours, days, and weeks can also be carried out without any problems in this operating mode.

Semi-automatic inspection | Manufacturing
A typical test in production can be performed manually using test probes or semi- or fully automatically. Thanks to its flexibility and user-friendly operator guidance , the GLP1-g is ideally suited for these applications. Up to 1,000 test sequences can be stored in the GLP1-g for testing different test objects. These can be started directly via the integrated touchscreen.

Fully Automated Testing | Mass Production
The GLP1-g integrates seamlessly into your production line. The unit’s dimensions are based on a ½ 19″ or 19″ enclosure, allowing the tester to fit perfectly into your system. Additional flexible interfaces enable convenient remote control. Connecting it to a control computer or a PLC is easy to implement.
You can store up to 1,000 test sequences for different test objects. You can access these directly via the interface and then start the test. All test results are accessible via the interface and can thus be stored in a central memory via the control computer. Additionally, it is possible to test results locally on the test device or directly on the computer network. save

Downloads
German PDFs

Do you need personalized product advice?
We'd be happy to provide provide you with comprehensive support and advice on all our products and services.
Give us a call or send us an email!