MTC2

Surge tester with 6, 12, 15, 25, 30, 40 or 50 kV

A deep look into the winding – the ultimate surge tester.
No other tester offers so much performance variety.

The MTC2 – ideal for laboratory, workshop and automation.
Perfectly enhanced with resistance, partial discharge, insulation resistance and high voltage testing.

Reliably test stators, armatures, coils and windings of all kinds.

More than 40 years of pioneering spirit, know-how, consistent optimization and permanent R & D activities of our engineers and technicians are the basis for this state-of-the-art surge tester.
Designed & Made in Germany.

Key-Facts

Winding tests in its purest form.

  • Class leading equipment features
  • Inspection of motors and generators up to 500 MW
  • Surge voltage up to 50 kV
  • Surge energy 125 Joule
  • High surge current 2.000 A
  • Fastest rise time 60 ns
  • Fully-integrated partial discharge test according to IEC 61934 and DIN EN 60034-18-41
  • Resistance measurement in 4-wire technology with temperature compensation
  • Insulation resistance test with automatic PI-measurement
  • Inductance test| LCR-inductance test bridge
  • Integrated armature test assistant, armature adapter and armature booster
  • 4 winding connections (windings + neutral point) plus frame connection
  • A number of tests can be performed without the necessity to reconnect connection leads
  • Easy and manual inspection without parameterization
  • Automatic test with subsequent Go/ NoGo – comparison
  • Result recording with test object-related data
  • Printing with any Windows-printers plus PDF
  • Data base for numerous test sequences and test results
  • Integrated high-quality industrial-PC with Windows®
  • Full network connectivity
  • Intuitive operation via touchscreen, mouse and keyboard
  • Possibility for remote maintenance or remote calibration
  • Remote control option for automation
  • Perfect for OEMs

Varianten

MTC2 6kV | Test method » Surge

type of testersurge testers
surge test0–6 kV
insulationall
 0–6 kV ˭
 Vmax like surge test
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
 like surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-HE | Test method » Surge

type of testersurge testers
surge test0–6 kV
insulationall
 0–6 kV ˭
 Vmax like surge test
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
 like surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3.6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R | Test methods » Surge · R

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-HE | Test methods » Surge · R

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3.6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-PD | Test methods » Surge · R · PD

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 6kV-R-PD-HE | Test methods » Surge · R · PD

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3,6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 6kV-Rack | Test method » Surge

type of testersurge testers
surge test0–6 kV
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-Rack | Test methods » Surge · R

type of testersurge testers
surge test0–6 kV
resistanceall
 4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-HE-Rack | Test methods » Surge · R

type of testersurge testers
surge test0–6 kV
resistanceall
 4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3.6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-PD-Rack | Test methods » Surge · R · PD

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 6kV-R-PD-HE-Rack | Test methods » Surge · R · PD

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3.6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 6kV-R-HVAC-Rack | Test methods » Surge · R · HVAC

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage ACall
 0–6 kV˜ max. 100 mA
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptinal
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-Caddy | Test method » Surge

type of testersurge testers
surge test0–6 kV
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-HE-Caddy | Test method » Surge

type of testersurge testers
surge test0–6 kV
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3.6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-Caddy | Test methods » Surge · R

type of testersurge testers
surge test0–6 kV
resistanceall
 4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-HE-Caddy | Test methods » Surge · R

type of testersurge testers
surge test0–6 kV
resistance4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3.6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-PD-Caddy | Test methods » Surge · R · PD

type of testersurge testers
surge test0–6 kV
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy1.8 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 6kV-R-PD-HE-Caddy | Test methods » Surge · R · PD

type of testersurge testers
surge test0–6 kV
resistanceall
 4-wire measurement
insulationall
 0–6 kV ˭
polarization indexVmax like surge test
high voltage DCall
 0–6 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy3.6 J
Surge current800 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 12kV | Test method » Surge

type of testersurge testers
surge test0–12 kV
insulationall
 0–12 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–12 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy7.2 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 12kV-HE | Test method » Surge

type of testersurge testers
surge test0–12 kV
insulationall
 0–12 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–12 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy14.4 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 12kV-R | Test methods » Surge · R

type of testersurge testers
surge test0–12 kV
resistanceall
 4-wire measurement
insulationall
 0–12 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–12 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy7.2 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 12kV-R-HE | Test methods » Surge · R

type of testersurge testers
surge test0–12 kV
resistanceall
 4-wire measurement
insulationall
 0–12 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–12 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy14.4 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 12kV-R-PD | Test methods » Surge · R · PD

type of testersurge testers
surge test0–12 kV
resistance4-wire measurement
insulationall
 0–12 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–12 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy7.2 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 12kV-R-PD-HE | Test methods » Surge · R · PD

type of testersurge testers
surge test0–12 kV
resistanceall
 4-wire measurement
insulationall
 0–12 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–12 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
automation
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy14.4 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 15kV | Test method » Surge

type of testersurge testers
surge test0–15 kV
insulationall
 0–15 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–15 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy11.25 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 15kV-HE | Test method » Surge

type of testersurge testers
surge test0–15 kV
insulationall
 0–15 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–15 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy22.5 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 15kV-R | Test methods » Surge · R

type of testersurge testers
surge test0–15 kV
resistanceall
 4-wire measurement
insulationall
 0–15 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–15 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy11.25 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 15kV-R-HE | Test methods » Surge · R

type of testersurge testers
surge test0–15 kV
resistanceall
 4-wire measurement
insulationall
 0–15 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–15 kV ˭
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy22.5 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 15kV-R-PD | Test methods » Surge · R · PD

type of testersurge testers
surge test0–15 kV
resistanceall
 4-wire measurement
insulationall
 0–15 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–12 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy11.25 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 15kV-R-PD-HE | Test methods » Surge · R · PD

type of testersurge testers
surge test0–15 kV
resistanceall
 4-wire measurement
insulationall
 0–15 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–15 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, Y, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads5 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance200 nF; customer-specific adaptation possible
Surge energy22.5 J
Surge current1000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 25kV | Test method » Surge

type of testersurge testers
surge test0–25 kV
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 25kV-3L | Test method » Surge

type of testersurge testers
surge test0–25 kV
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
test terminalsT1, T2, T3, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads4 | automatic switch-over in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 25kV-RF | Test methods » Surge · R

type of testersurge testers
surge test0–25 kV
resistanceall
 4-wire measurement
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the front
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 25kV-R | Test methods » Surge · R

type of testersurge testers
surge test0–25 kV
resistanceall
 4-wire measurement
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 25kV-R-3L | Test methods » Surge · R

type of testersurge testers
surge test0–25 kV
resistanceall
 4-wire measurement
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
test terminalsT1, T2, T3, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads4 | automatic switch-over in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 25kV-RF-PD | Test methods » Surge · R · PD

type of testersurge testers
surge test0–25 kV
resistanceall
 4-wire measurement
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
partial dischargeall
 in case of surge test
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the front
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 25kV-R-PD | Test methods » Surge · R · PD

type of testersurge testers
surge test0–25 kV
resistanceall
 4-wire measurement
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
partial dischargeall
 in case of surge test
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the front
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 25kV-R-PD-3L | Test methods » Surge · R · PD

type of testersurge testers
surge test0–25 kV
resistanceall
 4-wire measurement
insulationall
 0–25 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–25 kV ˭
partial dischargeall
 in case of surge test
test terminalsT1, T2, T3, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the front
Number of test leads4 | automatic switch-over in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy31.25 J
Surge current1600 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial dischargewith microwave antenna
with signal coupling in the test leads

MTC2 30kV | Test method » Surge

type of testersurge testers
surge test0–30 kV
insulationall
 0–30 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–30 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads3| manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy45 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 30kV-3L | Test method » Surge

type of testersurge testers
surge test0–30 kV
insulationall
 0–30 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–30 kV ˭
test terminalsT1, T2, T3, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads4 | automatic switch over in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy45 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 30kV-RF | Test methods » Surge · R

type of testersurge testers
surge test0–30 kV
resistance4-wire measurement
insulationall
 0–30 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–30 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the front
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy45 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 30kV-R | Test methods » Surge · R

type of testersurge testers
surge test0–30 kV
resistanceall
 4-wire measurement
insulationall
 0–30 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–30 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy45 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 30kV-R-3L | Test methods » Surge · R

type of testersurge testers
surge test0–30 kV
resistanceall
 4-wire measurement
insulationall
 0–30 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–30 kV ˭
test terminalsT1, T2, T3, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads4 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy45 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 40kV | Test method » Surge

type of testersurge testers
surge test0–40 kV
insulationall
 0–40 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–40 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy80 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 40kV-3L | Test method » Surge

type of testersurge testers
surge test0–40 kV
insulationall
 0–40 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–40 kV ˭
test terminalsT1, T2, T3, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads4 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy80 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 40kV-RF | Test methods » Surge · R

type of testersurge testers
surge test0–40 kV
resistanceall
 4-wire measurement
insulationall
 0–40 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–40 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the front
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy80 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 40kV-R-3L | Test methods » Surge · R

type of testersurge testers
surge test0–40 kV
resistanceall
 4-wire measurement
insulationall
 0–40 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–40 kV ˭
test terminalsT1, T2, T3, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads4 | automatic switchover in the tester
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy80 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 50kV | Test method » Surge

type of testersurge testers
surge test0–50 kV
insulationall
 0–50 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–50 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the rear
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clamps
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy125 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

MTC2 50kV-RF | Test methods » Surge · R

type of testersurge testers
surge test0–50 kV
resistanceall
 4-wire measurement
insulationall
 0–50 kV˭
polarization indexVmax like surge test
high voltage DCall
 0–50 kV ˭
test terminalsK1, K2, frame
test coverpossible
deliveryorder-related manufacturing
Test leadspluggable at the front
Number of test leads3 | manual switchover at the DUT
Housing test lead1 | stator/motor housing
Kelvin clampsoptional
Surge capacitance100 nF; customer-specific adaptation possible
Surge energy125 J
Surge current2000 A; customer-specific adaptation possible
Pulse rise time100 – 500 ns; according to IEC 60034-18-41
Partial discharge

Beschreibung

Intuition – Function – Perfection.

The MTC2 is our premium surge voltage tester – no other tester offers such a diversity of features. With the MTC2 you inspect coils, stators, armatures and all kinds of windings according to the latest state of the art – uncompromising and precise.

Innovations, technology lead and a patented analytical method for surge voltage characterize the MTC2-surge voltage testers of the 6th generation.
A finely graduated variety of testers from 6 kV up to 50 kV  is available.

Based on 25 years experience, extensive know-how and consistent optimization you get THE „state-of-the-art surge voltage tester“.

What makes the MTC2 so special?

4 connection leads

4 connection leads offer the possibility to contact all relevant winding connections at the same time. The 3 phase connections and the neutral point are connected to the 4 connection leads.  In this way it is possible to achive a unique test accuracy.

Automatic test method switch-over

As soon as the test object is connected, the MTC2 automatically measures at all 4 connections. Thanks to the integrated test method switchover, there´s no need for manual re-clamping. This saves time and avoids mistakes.

Advanced surge voltage

The surge voltage test with standard-compliant rise time leaves no defect undetected. Modern, automatic evaluations facilitate the fault analysis.

Optional partial discharge test with surge voltage 

The innovative, standard-compliant partial discharge test can easily be integrated. It gives you information about critical insulation weaknesses and the suitability for operation with frequency converters.  SCHLEICH pursues two strategies to obtain good test results at stators as well as at entirely-assembled motors: Measurement via coupler in the measuring lead (perfect for motors) and measurement via antenna (perfect for stators).

Optional precise resistance measurement in 4-wire-technology

To achieve precise measuring results by comparing the three phases´resistances , the resistance is measured in 4-wire technology.  Of course, the 4-wire technolgy is also applied by means of the automatic test method switchover!

Optional high-voltage test with AC 

In addition, you can also perform a high-voltage test with AC.  Of course,  the automatic test method switchover is also applicable in this case. 

Optional rotor- / stator test

The measuring technology allows you to find faults in rotors or stators and to detect broken bars in the squirrel-cage rotor.


Technik

Automation and Interfaces.

  • digital I/O, (input/output 24 V to PLC)
  • RS232 via SCHLEICH communication protocol
  • LAN via SCHLEICH communication protocol
  • LAN via TCP/IP
  • individual special solution …

 

Benefits of measurement technology at a glance.

Voltage supply

  • Voltage range 90 – 250 V, 47 – 63Hz
  • key switch for unlocking

Connections

  • 4 + laminated core (ground)

Autotest

  • automatic stator-, motor inspection
  • fully-automatic fault analysis

Surge voltage

  • 6, 12, 15, 25, 30, 40 and 50 kV
  • automatic and manual surge voltage test
  • 1-, 2- and 3-phase
  • automatic evaluation
  • 8 different evaluation methods incl. correlation (patented by SCHLEICH)
  • optional armature booster to inspect DC armatures

High-voltage DC

  • 6, 12, 15, 25, 30, 40 and 50 kV
  • manually adjustable
  • automatically programmable
  • step voltage measurement

Insulation resistance DC

  • 6, 12, 15, 25, 30, 40 and 50 kV
  • according to VDE 0701
  • 1 MΩ – 100 GΩ

Polarization index

  • 6, 12, 15, 25, 30, 40 and 50 kV
  • PI-measurement
  • DAR-measurement
  • automatic measurement

Partial discharge Surge – Option

  • 6, 12, 15 and 25 kV
  • according to DIN EN 60034-18:2014
  • Measurements of
    • PDIV – Partial discharge inception voltage
    • RPDIV – Repetitive partial discharge inception voltage
    • RPDEV – Repetitive partial discharge extinction voltage
    • PDEV – Partial discharge extinction voltage
  • Measurements via coupler in the test lead – perfect for motors
  • Measurements via antenna – perfect for stators

Resistance- Option

  • 1-, 2- and 3-phase
  • 1 mΩ – 100 kΩ
  • imbalance inspection
  • 4-wire technology
  • ambient temperature compensation

High-voltage AC – Option

  • up to 6 kV, 100 mA
  • 1-, 2- and 3-phase

 

⇒ Find more details under Downloads.


Anwendungen

Motor repair | Manual inspection

Schleich_MTC2_manual stator inspection

SCHLEICH_MTC2_manual stator inspection

The MTC2 is immediately ready to perform spontaneous measurements. By means of the unique manual mode all test methods (resistance-, surge voltage,- insulation resistance- and partial discharge test) may be started.  There´s no need for test parameterizations in advance. You only enter the requested test voltage and start the test.

The software always provides you, similar to a multimeter, with the current test results.  Thus, the evaluation of the winding and its´insulating system is instantly possible and you are able to decide if the motor needs a repair and what needs to be repaired.

In addition, a variety of motor data can be entered, which can also be printed, together with the test results, on the SCHLEICH standard test report.


Motor repair | Manual inspection of squirrel cage rotors or stators

SCHLEICH_MTC2_manual inspection
By means of special test probes a turn-to-turn fault in the stator is determined. This procedure may also be applied at squirrel cage rotors.

 See also : Rotor-Stator-Check


Motor repair| Manual rotor inspection

SCHLEICH_MTC2_manual rotor inspection
By means of special test probes and the armature booster the rotor is inspected from bar to bar. Usually it is tested between two adjacent bars. A quadrant- or  semicircle measurements also possible. The operator is led through the test by the integrated armature booster software.

 

SCHLEICH_MTC2_armature booster
In this case the armature booster is used for direct measurements at a train.

 See also: Armature booster in SchleichPedia


Motor repair| Fully-automatic inspection

Schleich_MTC2
In the repair sector, a great variety of motors and generators may be fully-automatic inspected.

For this, the MTC2 offers a fully-automatic mode, which is perfectly-suited for use the in electrical engineering industry.  There are 3 options to use it:

First option
As standard, the MTC2 is already equipped with a great number of test sequences for any arbitrary nominal voltage classes. Those are already pre-set for the different test tasks and may not be adjusted. Thanks to this, you can immediately start, even in the fully-automatic mode. The operator only has to select the test sequence according to the motor´s nominal voltage and connect the motor or stator.  Then he can start the fully-automatic test with automatic Go/ NoGo evaluation.
Es ist kein technisch geschultes Personal notwendig, um die Messwerte korrekt zu beurteilen!

Second option
In the fully-automatic mode the test is performed according to a freely-definable test sequence. The tester evaluates the measuring results fully-automatically and displays them either in red (NoGo) or in green colour (GO) on the screen. There´s no need for special trained or skilled staff to properly evaluate the measured results.
A nearly unlimited number of test sequences may be entered, which may be ideally adapted to and optimized for your test situation and tasks.

Third option
All saved tests may be accessed at any time and further measurements based on these settings may be performed. By this you get a direct comparison to former test results.


Motor production

Schleich_MTC2_motor production
The MTC2 may be easily integrated in your production line. The cabinet´s dimensions are based on a 19″-housing in which the tester may perfectly be integrated.  Additional interfaces allow an entire remote-control by the master PC.

For different kids of test objects any arbitrary number of test sequences may be saved in the MTC2 and accessed and started via the interface.

All test results are accessible via the interface and may be stored in a central data base by means of the master PC. Furthermore it´s possible to save the results either locally on the tester or directly in the network.


Further impressions

MTC2 on its way to the scene 

  • Robust, solid test technology
  • Use on major construction site in South America
SCHLEICH_MTC2_portable Motor inspection with the portable MTC2

  • The mobile use is very important for all MTC2-users
SCHLEICH_MTC2_inspection of broken winding Inspection of a broken winding 

  • test before
  • test after
  • Test report printout with input- and output data
SCHLEICH_MTC2_inspection DC motors Inspection of DC motors 

  • Inspection from bar to bar
  • The armature assistent leads you through the test
Testing without limits

  • The MTC2 is suitable for numerous applications and tasks

Zubehör

Abbildung druckansicht

Kelvinzangen

High-precision resistance measurement even for smallest resistances
  • condition for high-precise resistance measurements
  • solid industrial quality
  • 3 different sizes
Abbildung druckansicht

Motorprüfstecker

Test plugs for contacting motor terminal boards
  • induction motor test plugs / motor terminal board plugs
  • quick contact for 6, 8 or 9 bolts
  • for different motor terminal board sizes
  • for threaded bolts M4, M5, M6, M8 and M10
  • without, with 1 or 2 motor grounding tips
  • super simple test lead connection
  • 4 patents pending
Abbildung druckansicht

Klemmenblock

Modular terminal blocks to contact loose lead ends
  • stackable 4-wire clamps
  • modular design
  • different designs and sizes
Abbildung druckansicht

Prüftische mit Rollen

Mobile test equipment use in your shop floor
  • mobility at testing
  • perfect for workshop applications
  • ergonomic design with storage space
Abbildung druckansicht

Barcodescanner

Scanning of serial numbers, product types, production specifications, ...
  • various 1D & 2D-barcode scanners
  • reading of order data, operator names, serial numbers and more
Abbildung druckansicht

Warnleuchten

Warning and indication of hazardous test voltage
  • warning of hazardous test voltage
  • only required for touchable test objects
  • not necessary when test cover is used
Abbildung druckansicht

Absperrung

For securing the testing area
  • mobile workplace protection
  • with integrated emergency stop, warning lights
  • built-in 2-hand start
Abbildung druckansicht

Fußtaster

Starting a test - Confirming a query
  • starting a test
  • confirming a query
Abbildung druckansicht

Einzelprüfhauben

Testing with protection against accidential contact
  • various sizes
  • ergonomic – smooth-running – versatile
  • sturdy industrial quality – long service life
  • up to Performance Level PLe
  • built-in result lights
  • plenty of space for adapter installations
  • optional: automatic opening – guard locking …
Abbildung druckansicht

Prüfkabinen

Testing with protection against accidential contact
  • with safety door or roller shutter
  • for large or bulky test objects
  • suitable for pallet trolleys
  • various sizes
  • robust industrial quality – long service life
  • up to Performance Level PLe
  • integrated door locking
  • custom solutions …
Abbildung druckansicht

Prüfdummy, Selbsttest-Blackbox

Dummy test used for standardized functionality control
  • for daily inspection
  • universal blackboxes
  • factory calibration, also according to DAkkS
  • SCHLEICH GmbH
  • An der Schleuse 11
  • 58675 Hemer | Germany
  • +49 (0) 23 72-94 98-0
  • +49 (0) 23 72-94 98-99
  • info(at)schleich.com