GLP2-MODULAR

Combination tester with up to 25 test methods

One step ahead.

The new generation of the GLP2 tester is a technological quantum leap. So much technology in this size can only be found at SCHLEICH. Based on our modular concept, it is compact and handy and offers an enormous variety of testing possibilities with precise, intelligent test sequences.

Its accuracy, its flexible application possibilities, the many interfaces, the integration into your company network, the fast test time and the optimally coordinated software ensure a fast return on investment.

Key-Facts

Universal testers for all kinds of electric products.

  • Class leading equipment features
  • PE / ground bond test up to 200 A
  • insulation test up to 10 kV
  • high-voltage test AC up to 100 kV
  • high-voltage test DC up to 100 kV
  • leakage current test 30 mA – 1 MHz
  • medical leakage current test 30 mA – 1 MHz
  • functional test 1- and 3-phase up to 120 A
  • for all combinations of safety- and functional tests
  • precision measurement technology for all test methods
  • PLe, SIL3, Kat4 Safety circuit (depending on device variant and degree of risk)
  • high process reliability
  • traceable calibration certificate included
  • customizable configurable testers and customized solutions
  • for 1 and 3-phase test objects
  • different housing designs
  • up to 250 programmable test connections
  • switch matrix modules for all types of test methods
  • multi stations with up to 3 test stations
  • test methods fully electronic controlled
  • full- and semi automatic running tests
  • manual tests
  • intuitive operating concept with 7″-touch display plus HDMI-interface
  • additional input with keyboard and mouse
  • reading of any 1D- and 2D-barcodes
  • Ethernet, Profibus, WLAN, USB and serial interfaces
  • communication via RS232 and/or SCPI-standard commands
  • data base for test plans and results
  • user administration
  • test report printout
  • freely-configurable label print for thermal transfer printers
  • several label printers controllable
  • full network connectivity
  • possibility for remote maintenance or remote calibration
  • remote control option for automation
  • perfect for OEMs
  • integrated „PLC-functionality“ with freely-programmable script-language


Beschreibung

Costumized modularity.

The GLP2-MODULAR provides unlimited possibilities to configure a tester perfectly matching to our customer´s individual specifications and expectations.

The unique multi-combination option is based on the Schleich Modular Concept. This concept has been developed to create customized, cost-effective testers, perfectly matching to your requirements and applications.

This modularity is realized by assembling all test methods in one compact tester in an innovative housing concept instead of installing several single testers in one big cabinet. This flexibility not only offers you a huge price benefit, furthermore each tester contains our engineers´ experience from over 14.000 installations. This experience flows consistently and without any compromise in further developments.

This is „customer based technology“ !

  • Test method switchover
    A specific SCHLEICH-feature is the integrated, automatic switchover between low-voltage and high-voltage tests. Thus, the test object may automatically be tested in only one test flow without the necessity of re-clamping the test connections. Thanks to this feature, it is possible to aquire cost-effective and individually-tailored multi testers.
  • Intuition
    Due to the tester´s intuitive and easy software, it is ideally suitable for your serial production with and without result documentation. It is also used for type tests and material inspection in laboratories.
  • Measurement technology
    Whoever belongs to the best, must put tomorrow´s standards into practice today! That is why the latest generation of GLP2-MODULAR testers has been technologically and optically perfected. Its´operating system is Windows© Embedded Compact 7, which is perfectly suitable for embedded systems. The operation is as expected: intuitive and logical. The measurement technology is without any compromise and underlines our claim to technological leadership.
  • Precision
    Our top priority is precision, the reproducibility of measured values and durability. Based on these characteristics, we are able to guarantee our customers a safe production, which, in turn, gives them the reassurance, to deliver only perfect and faultless goods to their customers.  This is how we together secure our position in the market.
  • Innovation
    The operation via touch screen and color-display is an innovation in the market.  This kind of operation has already become standard in the GLP2-class 10 years ago. Count on our long experience! The entire operation is driven by finger touching the symbols in the graphic display.  You can also enter numbers and letters by activating the virtual keyboard. With this feature, SCHLEICH once more proves its technological leadership. In addition, you can also connect a normal keyborad, a mouse and/ or a barcode scanner.
  • Connectivity
    As a standard, the GLP2-MODULAR is equipped with a 4 GB memory, which offers enough capacity for almost unlimited numbers of test sequences and test results. The test results may either be printed, stored on a USB-stick oder saved on a server in your network.  At the end of a test you can even print nameplates on a thermo transfer printer and document the certified quality to your customer.
  • Networking
    The GLP2-MODULAR may easily be integrated in networks. The number of GLP2-MODULAR testers in the network is unlimited.  Also test sequences and test results are stored in the network. Thus, all testers are able to access the same test sequences.
YouTube

Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube.
Mehr erfahren

Video laden


Technik

Automation and Interfaces.

  • digital I/O, (input/output 24 V to PLC)
  • RS232 via SCHLEICH communication protocol
  • LAN via SCHLEICH communication protocol
  • LAN via SCPI commands
  • LAN via TCP/IP socket communication (individual special software required)
  • PROFIBUS
  • PROFINET
  • EtherCAT
  • CANopen
  • individual special solution …

 

Benefits of measurement technology at a glance.

Measurement technology

  • rrecise and fast measurements
  • TRMS – true R.M.S. measurement
  • R.M.S.- and peak value measurement
  • effective- and apparent current measurement, cosφ
  • effective- and apparent power measurement

PE/ Ground AC

  • PE/ Ground resistance AC
  • 10 – 200 A AC, adjustable, electronically controlled
  • 6,12,18 V AC

PE/ Ground DC

  • PE/ Ground resistance DC
  • 1 – 200 A DC, adjustable, electronically controlled

Insulation DC

  • insulation resistance
  • 30 – 10.000 V DC, adjustable, electronically controlled
  • 100 kΩ – 10 GΩ
  • „warm insulation resistance test“

High-voltage AC

  • 50 – 100.000 V AC, adjustable
  • with safety current limiting max. 3 mA
  • without safety current limiting max. 2 A
  • ARC-detection
  • „Warm high-voltage test“

High-voltage DC

  • 50 – 50.000 V DC, adjustable, electronically controlled
  • with safety current limiting max. 4 mA
  • without safety current limiting max. 100 mA
  • „warm high-voltage test“

Function AC

  • 1- and 3-phase
  • range 1 – 690 V AC
  • max. 120 A
  • apparent-, active and reactive/ idle power
  • cos φ
  • incl. short-circuit test

Function DC

  • von 1 – 500 V DC
  • max. 120 A
  • incl. short-circuit test

Leakage current

  • according to standard EN60990 & EN60601 & various UL-Standards
  • 0,1 μA – 30 mA
  • R.M.S., peak value, DC-/AC share
  • Frequency range up to 1 MHz
  • medical
    • patient leakage current measurement
    • patient auxiliary leakage current
    • touch current measurement– between 2 test probes
    • patient interfaces 8 – extendable on request
    • operational ground of the test object
    • two test probe connections
    • insulated contactings S2 & S3

Equivalent leakage current

  • according to standard with conversion to any rated voltage

Residual voltage

  • 1- and 3-phase

Resistance

  • 1 mΩ – 500 MΩ
  • 4-wire technology

Inductance

  • impedance measurement via integrated measuring bridge
  • 4-wire technology

Capacity

  • capacity measurement via integrated measuring bridge
  • 4-wire technology

Internal resistance

  • battery´s internal resistance
  • 1 μΩ – 10 Ω
  • 4-wire technology

 

⇒ Find more details under Downloads.


Anwendungen

Test station – Repair station – laboratory |Manual test

Schleich_GLP2-ce_Production

By the unique manual mode, all test methods integrated in the tester may directly be applied.
No test sequence parameterization is required in advance. You only have to select the requested test method and start the test.
The software shows, similar to a multimeter, the currently measured test values. Thus, the evaluation of your test object is immediately and detailed possible.


Production| Semi- or fully automatic test

SCHLEICH_GLP2-ce modular semi-or full automatic test

Schleich_GLP2-ce_Serial-Production

Typical tests in production are either performed manually with test probes and/ or fully-automatic. Thanks to the convenient user guidance the GLP2-ce offers perfect testing conditions for these applications.

For the inspection of different kinds of test objects you can save up almost unlimited test sequences in the GLP2-ce, which can be opened and started by using the touch display, the keyboard or by scanning the barcode.
On request, the tester automatically generates a label at the end of a test.

Furthermore, you can also save a lot of order data, which can additionally be printed on the standard test report from SCHLEICH.

A further application may be the entire inspection of a train cabling with high currents and high voltage. For this, SCHLEICH developed a special tester.

SCHLEICH_GLP2-ce modular_inspection of train cabling


High-voltage test

Schleich_GLP2-ce_manuel

A further, typical application for the GLP2-ce is the high-voltage test up to 100 KV AC or DC.

The test voltage is generated by an external high-voltage transformer, which is remote-controlled by the tester. The high-voltage is connected to a barrel. At the top of the barrel the contactting to the test object is installed. The high-voltage´s opposite pole is the protective earth/ ground bond.

 

High-voltage test 6.000 V:

YouTube

Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube.
Mehr erfahren

Video laden


Zubehör

Abbildung druckansicht

editor&printer

PC-Software for editing test sequences and for storing and printing test results.
  • creating test sequences centrally in the network
  • storing test results in the network
  • evaluation and printout
Abbildung druckansicht

analyzer

PC-Software for statistical analysis of test results
  • in-depth test result analysis
  • production online monitoring
  • informative statistics-report printout
Abbildung druckansicht

Zweihandbedienung

Protection against electrical hazards
  • dual-circuit safety with BG-approval
  • solid and stable
  • 2 different models
Abbildung druckansicht

Anschlusskästen

Connection panel for connecting your device under test
  • 1, 2, 3 or 4 test sockets for different country standards
  • quick pressure clamps for single leads
  • 4 mm laboratory sockets
  • high current socket for protective conductor test probe
  • for single-phase and three-phase test objects
  • customized solutions
Abbildung druckansicht

comBOX » Leuchtenprüfung

Connect luminaires, test, dim, parameterize...
  • for LED and tube lights
  • integrated interfaces
  • DALI, DSI, Analog, Touch/Push, DMX, NFC, und more …
  • optimized test functions for the lighting industry
Abbildung druckansicht

Prüfdummy, Selbsttest-Blackbox

Dummy test used for standardized functionality control
  • for daily inspection
  • universal blackboxes
  • factory calibration, also according to DAkkS
Abbildung druckansicht

Warnleuchten

Warning and indication of hazardous test voltage
  • warning of hazardous test voltage
  • only required for touchable test objects
  • not necessary when test cover is used
Abbildung druckansicht

Hochspannungsprüfpistolen

Safe testing with high voltage
  • for 6, 10 or 12 KV AC/DC
  • without or with integrated start button
  • optional with 4-wire technology (4W)
Abbildung druckansicht

Prüfsonden

For manual PE, insulation resistance and leakage current tests
  • built-in start button
  • built-in 3-color LED
Abbildung druckansicht

Barcodescanner

Scanning of serial numbers, product types, production specifications, ...
  • various 1D & 2D-barcode scanners
  • reading of order data, operator names, serial numbers and more
Abbildung druckansicht

Etikettendrucker

Label printing of type plates, device and test result decals, ...
  • various thermal transfer printers
  • printout with order data, serial number, and more
Abbildung druckansicht

Einzelprüfhauben

Testing with protection against accidential contact
  • various sizes
  • ergonomic – smooth-running – versatile
  • sturdy industrial quality – long service life
  • up to Performance Level PLe
  • built-in result lights
  • plenty of space for adapter installations
  • optional: automatic opening – guard locking …
Abbildung druckansicht

Prüfkabinen

Testing with protection against accidential contact
  • with safety door or roller shutter
  • for large or bulky test objects
  • suitable for pallet trolleys
  • various sizes
  • robust industrial quality – long service life
  • up to Performance Level PLe
  • integrated door locking
  • custom solutions …
Abbildung druckansicht

Sicherheitslichtvorhang

Testing without protection against accidental contact
  • 1-, 2-, 3- or 4-sided open and monitored
  • two-channel monitoring of safety
  • for large or bulky test objects
  • accessible by pallet jack
  • marking of the approved test area
  • installation of contacts and clamps
  • various sizes
  • custom solutions …
Abbildung druckansicht

Prüffelder

Testing with protection against accidential touch
  • individual special solutions
  • multiple access doors
  • for large or bulky test objects
  • passable with fork lift truck
  • robust industrial quality – long service life
  • up to Performance Level PLe – evaluation with safety PLC
  • several emergency stop buttons and warning lights
  • integrated door locking …
Abbildung druckansicht

Sonderprüfhauben

Test covers – individually designed and crafted to meet your specifications
  • individual customer-specific solutions of any kind, application and size
Abbildung druckansicht

Prüftische

Individually designed and custom-made.
  • professional test tables:
  • according to BG-guidelines
  • customized for your test task
Abbildung druckansicht

Prüftische mit Rollen

Mobile test equipment use in your shop floor
  • mobility at testing
  • perfect for workshop applications
  • ergonomic design with storage space
Abbildung druckansicht

Absperrung

For securing the testing area
  • mobile workplace protection
  • with integrated emergency stop, warning lights
  • built-in 2-hand start
Abbildung druckansicht

Lüsterklemmenadapter

Contacting of 2-, 3- and 5-pole luster terminals
  • fast contacting with locking
  • up to 16 A
Abbildung druckansicht

Kelvinzangen

High-precision resistance measurement even for smallest resistances
  • condition for high-precise resistance measurements
  • solid industrial quality
  • 3 different sizes
Abbildung druckansicht

Pneumatische Klemme

Automatic pneumatic quick clamping
  • automatic clamp with pneumatic cylinder
  • push-button for fast release
  • for different wire diameters
  • hole diameter with 4, 6 or 9 mm
Abbildung druckansicht

Sonderkontaktierungen

Customized solutions based on the modular SCHLEICH building kit
  • individual solutions
  • for perfect 4-wire measurement
  • float-mounted collets
Abbildung druckansicht

Ergebnisleuchten

Test result pass or fail
  • what is the test result?
  • green: go – pass – OK
  • red: no go – fail – not OK
Abbildung druckansicht

Fußtaster

Starting a test - Confirming a query
  • starting a test
  • confirming a query
Abbildung druckansicht

Hochspannungsrelais – Anlagenkomponenten für den Eigenbau

Switching and disconnecting high voltages safely
  • high-voltage relays
  • switch matrixes
  • safe isolation
  • with single or double changeover contacts
  • SPDT “Single Pole Double Throw“
  • for rail mounting DIN50022
  • system components for DIY
Abbildung druckansicht

Hochspannungskabel

Safe conducting and distribution
  • for a variety of applications
  • cables up to 100 kV
Abbildung druckansicht

Hochspannungsstecker – Anlagenkomponenten für den Eigenbau

Connect high-voltage
  • for different applications and tasks
  • up to 100 kV
Abbildung druckansicht

Kalibrierwiderstände

High precision for verifying measurement accuracy
  • precision resistors for the annual calibration
  • low drift
  • factory calibration
  • DAkkS calibration (optional)
  • SCHLEICH GmbH
  • An der Schleuse 11
  • 58675 Hemer | Germany
  • +49 (0) 23 72-94 98-0
  • +49 (0) 23 72-94 98-99
  • info(at)schleich.com