Testing with protection against accidental contact

Safe ⋅ dual-channel monitoring ⋅ solid industrial quality ⋅ up to performance level PLe ⋅ integrated guard locking ⋅ long service life ⋅ Integrated guard locking ⋅ alternating testing and loading …

Key-Facts

Perfect protection against accidental contact.

  • great variety of standard test covers
  • mechanically solid and durable constructions
  • integrated result lights
  • space for clamps and contactings
  • automatic start when cover is closed
  • immediate interruption when opening the cover during tests
  • two-channel safety limit switches with monitoringup to Performance Level PLe
  • transparent test cover to observe the test object during the test
  • integrated cover lock
  • customized solutions for automatic production lines
  • customized solutions for fixtures for the placing of your DUT
  • customized solutions for the installation of manual contactings
  • customized solutions for the installation of automatic contactings

Varianten

Dual test cover M3-800-617-500

test cover typedouble test cover
model rangemodel 3
width x depth x height (inside)385 x 536 x 345 mm
width x depth x height (outside dimensions)800 x 617 x 500 mm
height of floor box75 mm
performance level (PL)reachable up to PLe; dual-channel monitoring
rated voltagemax. 6 kV AC / 8 kV DC
LED result lightsGO / NO GO - integrated in the test area
warning lightsoptional 2 pieces
safetyCAT IV
limit switch2 x CAT IV limit switches, contactless
automatic openingnot possible
automatic guard closingnot possible
guard locking during the testyes
industrial socket for test cableprepared for 2 pieces
carrying capacity of the base20 kg; 50 kg optional / 44 lbs; 110 lbs optional
ESD designoptional
Faraday cage designoptional
table frameoptionally with adjustable feet
 optionally with castors
installed on rolling containeroptional
CAD data availableyes, on request
deliveryorder-related manufacturing
order number401461

Dual test cover M3-1000-617-500

test cover typedouble test cover
model rangemodel 3
width x depth x height (inside)488 x 536 x 345 mm
width x depth x height (outside dimensions)1000 x 617 x 500 mm
height of floor box75 mm
performance level (PL)reachable up to PLe; dual-channel monitoring
rated voltagemax. 6 kV AC / 8 kV DC
LED result lightsGO / NO GO - integrated in the test area
warning lightsoptional 2 pieces
safetyCAT IV
automatic openingnot possible
automatic guard closingnot possible
guard locking during the testyes
industrial socket for test cableprepared for 2 pieces
carrying capacity of the base20 kg; 50 kg optional / 44 lbs; 110 lbs optional
ESD designoptional
Faraday cage designoptional
table frameoptionally with adjustable feet
 optionally with castors
installed on rolling containernot possible
CAD data availableyes, on request
deliveryorder-related manufacturing
order number4014948

Dual test cover M3-1200-617-500

test cover typedouble test cover
model rangemodel 3
width x depth x height (inside)588 x 536 x 345 mm
width x depth x height (outside dimensions)1200 x 617 x 500 mm
height of floor box75 mm
performance level (PL)reachable up to PLe; dual-channel monitoring
rated voltagemax. 6 kV AC / 8 kV DC
LED result lightsGO / NO GO - integrated in the test area
warning lightsoptional 2 pieces
safetyCAT IV
limit switch2 x CAT IV limit switches, contactless
automatic openingnot possible
automatic guard closingnot possible
guard locking during the testyes
industrial socket for test cableprepared for 2 pieces
carrying capacity of the base20 kg; 50 kg optional / 44 lbs; 110 lbs optional
ESD designoptional
Faraday cage designoptional
table frameoptionally with adjustable feet
 optionally with castors
installed on rolling containernot possible
CAD data availableyes, on request
deliveryorder-related manufacturing
order number4014949

Dual test cover M3-1400-617-500

test cover typedouble test cover
model rangemodel 3
width x depth x height (inside)688 x 536 x 345 mm
width x depth x height (outside dimensions)1400 x 617 x 500 mm
height of floor box75 mm
performance level (PL)reachable up to PLe; dual-channel monitoring
rated voltagemax. 6 kV AC / 8 kV DC
LED result lightsGO / NO GO - integrated in the test area
warning lightsoptional 2 pieces
safetyCAT IV
automatic openingnot possible
automatic guard closingnot possible
guard locking during the testyes
industrial socket for test cableprepared for 2 pieces
carrying capacity of the base20 kg; 50 kg optional / 44 lbs; 110 lbs optional
ESD designoptional
Faraday cage designoptional
table frameoptionally with adjustable feet
 optionally with castors
installed on rolling containernot possible
CAD data availableyes, on request
deliveryorder-related manufacturing
order number4014950

Dual test cover M12-1860-1175

test cover typedouble test cover
model rangemodel 12
performance level (PL)reachable up to PLe; dual-channel monitoring
rated voltagemax. 6 kV AC / 8 kV DC
LED result lightsGO / NO GO - integrated in the test area
automatic openingnot possible
automatic guard closingnot possible
guard locking during the testyes
carrying capacity of the base50 kg; 150 kg optional / 110 lbs; 330 lbs optional
ESD designoptional
Faraday cage designoptional
table frameoptionally with adjustable feet
 optionally with castors
installed on rolling containernot possible
CAD data availableyes, on request
deliveryorder-related manufacturing

Dual test cover 2xM1-1092-792-520

test cover typedouble test cover
model rangemodel 1
performance level (PL)reachable up to PLe; dual-channel monitoring
rated voltagemax. 8 kV AC / 10 kV DC
LED result lightsGO / NO GO - integrated in the test area
opening angle of the test coveralmost 90° mechanical
automatic openingoptional
automatic guard closingnot possible
guard locking during the testnot possible
industrial socket for test cableprepared for 2 pieces
carrying capacity of the base15 kg; 50 kg optional / 33 lbs; 110 lbs optional
ESD designoptional
Faraday cage designnot possible
table frameoptionally with adjustable feet
 optionally with castors
installed on rolling containeroptional
CAD data availableyes, on request
deliveryorder-related manufacturing

Dual test cover 2xM1-1492-792-520

test cover typedouble test cover
model rangemodel 1
performance level (PL)reachable up to PLe; dual-channel monitoring
rated voltagemax. 8 kV AC / 10 kV DC
LED result lightsGO / NO GO - integrated in the test area
opening angle of the test coveralmost 90° mechanical
automatic openingoptional
automatic guard closingnot possible
guard locking during the testnot possible
industrial socket for test cableprepared for 2 pieces
carrying capacity of the base15 kg; 50 kg optional / 33 lbs; 110 lbs optional
ESD designoptional
Faraday cage designnot possible
table frameoptionally with adjustable feet
 optionally with castors
installed on rolling containeroptional
CAD data availableyes, on request
deliveryorder-related manufacturing

Beschreibung

Protection devices with automatic protection against accidential contact

With the main focus on ergonomics and reliability, SCHLEICH test covers are a solid, long-lasting investment in reducing the risk of the operator. The DUT is safely covered so that it cannot be touched.

The smooth-running cover made of break-proof, transparent plastic covers the DUT and allows visual monitoring during the test. Testing is only possible when the test cover is closed. The status of the test cover is continuously monitored by a two-circuit safety-limit switch in conjunction with a safety-analysis module, which is approved and compliant with standards. This two-circuit safety switch meets the requirements for automatic protection against accidential contact.

Closing the test cover starts the test process. Opening the test cover while the test is still in process will lead to immediate interruption. The voltage is released and the DUT is unloaded. It is possible to add a safety lock, which prevents that the cover is opened during the test.

The test covers can be used together with individual mechanical fixtures. The fixture can be firmly mounted on the base plate or it can come with an adapter. The test cover contains connections for contacting the test leads. Connection leads to the testers are, in general, firmly connected at the rear. The connection to the tester is realized with plug connectors.

With the optional lock the test cover remains closed:

  • until the DUT has been fully discharged
  • until a mechanical motion or rotation has been completed
  • in case of a negative test result (NO GO)

The complete isolation of the test area prevents voltages being exposed outside the enclosure. The operating personnel is optimally protected.

In order to protect sensitive DUTs from electrostatic charging and discharge, the test covers can be made of ESD-materials (for additional charge).

 


Technik

Connection options

SCHLEICH test covers offer a variety of connection options for the safe feed-through of leads.

 


Zubehör

Abbildung druckansicht

Anschlusskästen

Connection panel for connecting your device under test
  • 1, 2, 3 or 4 test sockets for different country standards
  • quick pressure clamps for single leads
  • 4 mm laboratory sockets
  • high current socket for protective conductor test probe
  • for single-phase and three-phase test objects
  • customized solutions
Abbildung druckansicht

Kelvinzangen

High-precision resistance measurement even for smallest resistances
  • condition for high-precise resistance measurements
  • solid industrial quality
  • 3 different sizes
Abbildung druckansicht

Klemmenblock

Modular terminal blocks to contact loose lead ends
  • stackable 4-wire clamps
  • modular design
  • different designs and sizes
Abbildung druckansicht

Sonderkontaktierungen

Customized solutions based on the modular SCHLEICH building kit
  • individual solutions
  • for perfect 4-wire measurement
  • float-mounted collets
Abbildung druckansicht

Pneumatische Klemme

Automatic pneumatic quick clamping
  • automatic clamp with pneumatic cylinder
  • push-button for fast release
  • for different wire diameters
  • hole diameter with 4, 6 or 9 mm
Abbildung druckansicht

Ergebnisleuchten

Test result pass or fail
  • what is the test result?
  • green: go – pass – OK
  • red: no go – fail – not OK
Abbildung druckansicht

Warnleuchten

Warning and indication of hazardous test voltage
  • warning of hazardous test voltage
  • only required for touchable test objects
  • not necessary when test cover is used
  • SCHLEICH GmbH
  • An der Schleuse 11
  • 58675 Hemer | Germany
  • +49 (0) 23 72-94 98-0
  • +49 (0) 23 72-94 98-99
  • info(at)schleich.com