High-voltage test pistols

Safe testing with high voltage

During manual high-voltage testing, the test pistol is used to contact the test object. Various versions and cable lengths are available for a wide variety of applications.

Key-Facts

Safety comes first.

  • Safety test pistols up to 10 KV and 12 KV
  • Safety test pistols with integrated start button in the handle
  • Safety test pistols with integrated start button in the pressure-sensitive test tip
  • Safety test pistols in 4-wire-technology
  • Different lead lengths

Varianten

HV test pistol, 10 kV DC / 8 kV AC, 2 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR, GLP3
cable length2 m
cable coloryellow
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 10 kV DC / 8 kV AC, 4 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR, GLP3
cable length4 m
cable coloryellow
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 10 kV DC / 8 kV AC, 6 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR, GLP3
cable length6 m
cable coloryellow
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 10 kV DC / 8 kV AC, 10 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR, GLP3
cable length10 m
cable coloryellow
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 8 kV AC, 2 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR
cable length2 m
cable colorred
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 8 kV AC, 5 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR
cable length5 m
cable colorred
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 8 kV AC, 10 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR
cable length10 m
cable colorred
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 8 kV AC with start button, 2 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR
cable length2 m
cable colorred
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 8 kV AC with start button, 5 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR
cable length5 m
cable colorred
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 8 kV AC with start button, 10 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR
cable length10 m
cable colorred
test voltagemax. 10 kV DC, 8 kV AC - 50-60 Hz
currentmax. 1 A
number of poles 1-pole

HV test pistol, 2-poles, 10 kV DC / 8 kV AC, 2 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR, GLP3
cable length2 m
cable colorblue
test voltagemax. 10 kV DC, 8 kV AC - 50 Hz
currentmax. 1 A
push buttonintegrated
number of poles 2-pole

HV test pistol, 2-poles, 10 kV DC / 8 kV AC, 4 m

for following testersGLP1-g, GLP2-BASIC, GLP2-MODULAR, GLP3
cable length4 m
cable colorblue
test voltagemax. 10 kV DC, 8 kV AC - 50 Hz
currentmax. 1 A
number of poles 2-pole
push buttonintegrated

HV test pistol, 2-poles, 10 kV DC / 8 kV AC, 6 m

for following testersGLP1-g
cable length6 m
cable colorblue
test voltagemax. 10 kV DC, 8 kV AC - 50 Hz
currentmax. 1 A
number of poles 2-pole
push buttonintegrated

HV test pistol, 2-poles, 10 kV DC / 8 kV AC, 10 m

for following testersGLP1-g
cable length10 m
cable colorblue
test voltagemax. 10 kV DC, 8 kV AC - 50 Hz
currentmax. 1 A
number of poles 2-pole
push buttonintegrated

HV test pistol, 15 kV DC / 12 kV AC AC, 2.5 m

for following testersGLP1-g, GLP2-MODULAR
cable length2.5 m
connectionspecial plug for 15 kV DC/12 kV AC connection socket
test voltagemax. 15 kV DC, 12 kV AC - 50 Hz
currentmax. 200 mA

HV test pistol, 15 kV DC / 12 kV AC AC, 6 m

for following testersGLP1-g, GLP2-MODULAR
cable length6 m
connectionspecial plug for 15 kV DC/12 kV AC connection socket
test voltagemax. 15 kV DC, 12 kV AC - 50 Hz
currentmax. 200 mA
order number40003237

Beschreibung

Safe testing with high-voltage.

At manual high-voltage tests the test object is contacted with high-voltage test pistols.

Different HV-test pistols for different test tasks are available.

Safety HV-test pistols allow a safe, manual contacting at single test points.

The test tip is made of almost wear-free lungsten and assures a long lifetime.  Furthermore the test tip is protected by an arc-resistant teflon tube.

The start button in the handle is protected against accidental activation.


Technik

Technology at a glance.

High-voltage test probe for testers with 3mA safety current limiting 

  • Lead length 2 m
  • Test voltage AC 1,5 KV
  • Test voltage DC 2 KV

High-voltage test pistols with trigger in the handle to extend the test tip

 

  • Lead length 2, 4, 6, 8, 10 m
  • Test voltage AC 8 KV
  • Test voltage DC 10 KV
  • High-voltage is not led through handle
  • Test tip diameter only 1,6 mm

High-voltage test pistols with trigger and button in the handle to extend the test tip

  • Lead length 2, 4, 6, 10 m
  • Test voltage AC 8 KV
  • Test voltage DC 10 KV

High-voltage test pistols with trigger to extend the test tip and integrated push button

The test is started by pressing the extended test tip against the test object.
By this, an internal switch is activated in the test pistols . The test is started, as soon as both switches are activated in the pistols .

  • Lead length 2, 4, 6 m
  • Test voltage AC 8 KV
  • Test voltage DC 10 KV

High-voltage test probe with trigger to extend the test tip

  • Lead length 2, 6, 10 m
  • Test voltage AC 12 KV
  • Test voltage DC 15 KV

High-voltage cable with connection plug 

  • Lead length 2, 4, 6, 8, 10 m
  • Test voltage AC 8 KV
  • Test voltage DC 10 KV

High-voltage cable with connection plug and alligator clamp

  • Lead length 2, 4, 6 m
  • Test voltage AC 8 KV
  • Test voltage DC 10 KV

Anwendungen

High-voltage test with safety test pistols.


Our safety test pistols are available either with or without integrated start button.
The picture shows test pistols without start button. Thus, either the start button at the tester´s front or the foot switch has to be activated to start the test.

 

Impressions

60204-test at a cabinet

Schleich_Prüfpistolen1

  • One-hand operation with release by an operating panel
  • Test between pistols and ground
  • Inspection of
    • PE-resistance with10 A
    • Insulation resistance
    • High-voltage AC or DC

High-voltage test

Schleich_Prüfpistolen2

  • Two test pistols

High-voltage test via adapter

Schleich_Prüfpistolen3

  • Adapter to connect the test object´s plug
  • Contact pads on the adapter where the test pistols are to be pressed on

High-voltage tests at motors

Schleich_Prüfpistolen4

  • Fault-to-frame test between winding and motor housing

High-voltage tester integrated in a mobile caddy 

Schleich_Prüfpistolen5

  • Perfect for mobile use
  • Integrated compartment on the right side of the tester
  • SCHLEICH GmbH
  • An der Schleuse 11
  • 58675 Hemer | Germany
  • +49 (0) 23 72-94 98-0
  • +49 (0) 23 72-94 98-99
  • info(at)schleich.com