Every motor manufacturer is familiar with the issue of time-consuming contacting of the motor terminal board.
Motor test plugs enable fast contacting of 6-, 8- or 9-pole motor terminal boards.
Key-Facts
Motor contacting. Productive. Reliable. Safe.
for motor terminal boards with bolt size M4, M5, M6, M8 and M10
for motor terminal boards with with 6, 8 or 9 threaded bolts
for motor terminal boards with defferent bolt spacings
very robust and quickly exchangeable collets
low contact resistance
for test voltages up to 6 kV HV AC and surge test
optionally with quick-change grounding tip(s)
suitable for high terminal boxes
version slim fit – suitable for compact narrow terminal boxes
handle for quick and convenient clamping of the motor test plug
perfect connection space for many test leads
slanted cover with large metric M40 threaded conduit fitting
optionally with installation space for 6 sense line fuses
Varianten
Motor Terminal Plug M4, 6 x 15 mm
threaded bolt size
M4
number of threaded bolts
6
threaded bolts spacing
15 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M4, 6 x 16 mm
threaded bolt size
M4
number of threaded bolts
6
threaded bolts spacing
16 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M4, 6 x 16 mm, slim fit
threaded bolt size
M4
number of threaded bolts
6
threaded bolts spacing
16 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M4, 8 x 16 mm
threaded bolt size
M4
number of threaded bolts
8
threaded bolts spacing
16 mm
grounding tips
0, 1 or 2
test voltage
6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug, M4, 8 x 16 mm, slim fir
threaded bolt size
M4
number of threaded bolts
8
threaded bolts spacing
16 mm
grounding tips
0, 1 or 2
test voltage
6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M4, 6 x 18 mm
threaded bolt size
M4
number of threaded bolts
6
threaded bolts spacing
18 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug, M4, 6 x 20 mm
threaded bolt size
M4
number of threaded bolts
6
threaded bolts spacing
20 mm
grounding tips
0, 1 or 2
test voltage
6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M4, 6 x 22 mm
threaded bolt size
M4
number of threaded bolts
6
threaded bolts spacing
22 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motorprüfstecker M4, 6 x 25 mm
threaded bolt size
M4
number of threaded bolts
6
threaded bolts spacing
25 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motorprüfstecker M5, 6 x 16 mm
threaded bolt size
M5
number of threaded bolts
6
threaded bolts spacing
16 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M5, 6 x 18 mm
threaded bolt size
M5
number of threaded bolts
6
threaded bolts spacing
18 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M5, 6 x 20 mm
threaded bolt size
M5
number of threaded bolts
6
threaded bolts spacing
20 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Test Plug M5, 6 x 23 mm
threaded bolt size
M5
number of threaded bolts
6
threaded bolts spacing
23 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M5, 6 x 24 mm
threaded bolt size
M5
number of threaded bolts
6
threaded bolts spacing
24 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M5, 6 x 25 mm
threaded bolt size
M5
number of threaded bolts
6
threaded bolts spacing
25 mm
grounding tips
0, 1 or 2
test voltage
max. 6kV
test current
max. 32 A
threaded conduit fitting
metric M40
Motor Terminal Plug M6, 6 x 26 mm
threaded bolt size
M6
number of threaded bolts
6
threaded bolts spacing
25 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 40 A
threaded conduit fitting
metric M40
Motor Terminal Plug M6, 6 x 28 mm
threaded bolt size
M6
number of threaded bolts
6
threaded bolts spacing
28 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 40 A
threaded conduit fitting
metric M40
Motor Terminal Plug M6, 6 x 30 mm
threaded bolt size
M6
number of threaded bolts
6
threaded bolts spacing
30 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 40 A
threaded conduit fitting
metric M40
Motor Terminal Plug M8, 6 x 30 mm
threaded bolt size
M8
number of threaded bolts
6
threaded bolts spacing
30 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 55 A
threaded conduit fitting
metric M40
Motor Terminal Plug M8, 6 x 35 mm
threaded bolt size
M8
number of threaded bolts
6
threaded bolts spacing
35 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 55 A
threaded conduit fitting
metric M40
Motor Terminal Plug M8, 6 x 42 mm
threaded bolt size
M8
number of threaded bolts
6
threaded bolts spacing
42 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 55 A
threaded conduit fitting
metric M40
Motor Terminal Plug M10, 6 x 44 mm
threaded bolt size
M10
number of threaded bolts
6
threaded bolts spacing
44 mm
grounding tips
0, 1 or 2
test voltage
max. 6 kV
test current
max. 70 A
threaded conduit fitting
metric M40
Beschreibung
Every electrical motor manufacturer knows the problem of time-consuming contacting of the motor terminal board.
In order to save a lot of time, SCHLEICH has developed a new motor terminal board connectors.
1. Production
✓ Ergonomic gripping with both hands. On the swivel lever and on the connector.
✓ Placing the motor test plug on the threaded bolts.
✓ Clamp by pressing the swivel lever into the horizontal position.
✓ Ready – start test.
2. Maintenance
✓ Changing the collets without disassembling the motor test plug into its individual parts.
✓ Change the grounding tip directly from the outside.
3. Connecting the test leads in the motor test plug
✓ Enough space is available for connection.
✓ Safe insulation by separators between the terminals and routing of the cables.
✓ Large M40 conduit with plenty of space for power and sense test leads.
Mit dem Laden des Videos akzeptieren Sie die Datenschutzerklärung von YouTube. Mehr erfahren