Square wave PD test with partial discharge analysis
Rapid voltage transients—keeping track of every single pulse
Modern inverters place high demands on insulation. Using the “ Square wave PD test ” for the MTC2 R7 , you can simulate these conditions realistically—and analyze voltage waveforms and partial discharge signals in direct temporal correlation.
For motors, stators, windings, and pulse-powered insulation systems in development, testing, and manufacturing.
- Unipolar up to 3 kV or 6 kV; bipolar ±3 kV
- Simultaneously Capture Voltage Pulses and PD Signals
- Analyze each test pulse individually
- Automatic GO/NOGO Assessment
- Turn-to-turn, phase-to-phase, phase-to-ground
Steep slopes make all the difference
From a square-wave pulse to a partial discharge signal: schematic test setup on the stator.
Rapid voltage changes place a different strain on the winding insulation than a slowly varying voltage voltage. During the rising edge of the pulse, the voltage can be distributed unevenly across the winding. The first few turns at the feed-in point, in particular, may be subjected to greater stress.
Square wave PD test combines this impulse loading with the detection of partial discharges. This allows for a targeted investigation of the behavior of the insulation system under high dU/dt loads.
Focus on the First Coils
Rapid voltage changes place a different strain on the winding insulation than a slowly varying voltage voltage. During the rising edge of the pulse, the voltage can be distributed unevenly across the winding. The first few turns at the feed-in point, in particular, may be subjected to greater stress.
Square wave PD test combines this impulse loading with the detection of partial discharges. This allows for a targeted investigation of the behavior of the insulation system under high dU/dt loads.
Qualitative illustration with a rise time of approximately 100 ns. The actual distribution depends, among other factors, on the winding geometry, parasitic capacitances, pulse shape, and connections.
Detailed Pulse Analysis
View the entire pulse sequence—and then examine each recorded test pulse individually. Clicking on the desired pulse in the device software opens its detailed view, including the corresponding partial discharge signal.

Original view of the impulse analysis. Blue: Voltage waveform. Red: Partial discharge signal.
Links: All related topics
The overview highlights differences within the pulse sequence. The selected pulse is highlighted.
On the right: the details for your review
Voltage transients and PD events can be time-stamped and analyzed in detail.
An In-Depth Look at the Insulation System
The combined display of " TEST VOLTAGE " and the PD signal helps you evaluate anomalies and further develop insulation concepts. " Square wave PD test " is suitable for various insulation sections:
- Coil – Coil
- Phase – Phase
- Phase – Earth
Faster test sequence with a clear result
To speed up the testing process, specify the number of pulses and the evaluation criterion. The system records the partial discharge activity and provides an automatic pass/fail evaluation (GO/NOGO) based on your threshold value.
1. Configuration – Set the number of pulses
Specify the number of test pulses—for example, 100 square-wave pulses.
2. Evaluate – Set Threshold
Specify the permissible percentage of pulses with detected partial discharge, for example, 10%.
3. Test – Read directly from result
Start the test. The color display makes the result immediately recognizable.

74% TE share—the example threshold of 10% has been exceeded.

The data refer to the measurement examples shown. The PD fraction refers to the proportion of pulses in which partial discharge was detected. The test time , and evaluation depend on the parameter settings and the test task.
Voltage Classes and Signal Shapes
Choose between unipolar and bipolar versions—depending on your testing requirements and the stresses placed on your insulation system.

3 kV unipolar
Square-wave pulses between 0 and +3 kV
Peak-to-Peak: 3 kV

6 kV unipolar
Square-wave pulses between 0 and +6 kV
Peak-to-Peak: 6 kV

± 3 kV bipolar
Set the number of pulses
Peak-to-Peak: 6 kV
The bipolar specification of ±3 kV describes both voltage levels and corresponds to 6 kV peak-to-peak. We will select the appropriate device model based on your testing requirements.
Twisted-pair testing with extremely fast pulse edges

Measurement example of a twisted-pair test. The detailed view helps correlate TE events with the selected pulse over time.
Test She twisted enameled wires with flexibly adjustable pulse widths and rise and fall times in the range of 40–70 n space . The TEST VOLTAGE and partial discharge signal show the behavior of the insulation during pulse stress.
Flexibly adjust pulse width
Adjust the pulse load to meet your test requirements.
Analyzing Edge Signals and PD Signals Together
Examine the behavior of the enameled wire insulation up to the individual test pulse.
MTC2 R7
Universal winding Test devices 6, 12, 15, 30, 40 and 50 kV
MTC2 winding Test systems are very compact, fully automatic high-end Test devices for a wide variety of winding goods in development, production, and Test laboratory.
For production, EOL, automation
For test laboratory, R&D, approval, certification tests
For repair, maintenance, and service
surge test
-
- Ultra-fast 50 measurements per second
- Phase comparison between phases
- Patented peak-to-peak measurement
Partial discharge compliant with DIN EN 60034-18:2014
-
- Passive or active antenna
- Conducted coupling
ohmic resistance
-
- Winding
- Temperature sensor
insulation resistance
-
- IR
- PI
- DAR
High voltage AC optional
Test connections
-
- Standard: 4
- Optional: 7 and more