Instant quote

Request your instant quote now. We will send you our quote within 1 to 24 hours.

"*"indicates required fields

Fields marked with * are mandatory.
Privacy Policy*

Test booths

Test mandatory touch protection

Test booths are protective devices that shield operators from electrical hazards and prevent contact with the test object during testing. They are available in various designs and sizes to cover almost all applications.

If there is no suitable standard solution available in our portfolio, we can also manufacture custom test chambers for you.

Key facts:

  • Mechanically robust and durable designs
  • Designed for tough use in industrial environments
  • Long service life and reliable operation
  • Safety door or rolling door
  • Ideal for large test objects
  • Accessible with pallet trucks
  • High-voltage test cabins

4 Product Variants

High-voltage test cabin PKT-1500-1500-2077

rated voltagemax. 6 kV AC / 8 kV DC
safetyUp to PL e, SIL 3, Cat. 4 achievable - Two-channel safety limit switch with certified evaluation device
Locking during testingoptional
LED scoreboard lightsGO n.GO built-in the test room
Load capacity of the floor2000 kg
CAD data availableYes, upon request
Availabilityin 15 business days
order number 40141028

Test cabin PKL-1440-1280-1900

safetyUp to PL e, SIL 3, Cat. 4 achievable - Two-channel safety limit switch with certified evaluation device
CAD data availableYes, upon request
Availabilityin 15 business days

High-voltage test cabin PKT-HV-720-650-740, Faraday cage

rated voltagemax. 50 kV AC/DC
safetyUp to PL e, SIL 3, Cat. 4 achievable - Two-channel safety limit switch with certified evaluation device
Locking during testingoptional
LED scoreboard lightsoptional
Load capacity of the floor150 kg
Can be mounted on table frameOptional with lifting table
Availabilityin 15 business days
order number 40005441
Show all 4 product variants

Perfect and secure touch protection

SCHLEICH test cabins SCHLEICH a rock-solid and long-lasting investment for minimizing hazards to the operator. Ergonomics and reliability are at the forefront.

A door protects test cabinets from contact with the test object. The smooth-running protective door made of shatterproof, transparent plastic device under test the device under test and allows visual inspection during testing. Tests can only be performed when the protective door is closed. The status of the protective door is continuously monitored by a standard-compliant, safety-approved, dual-circuit safety limit switch in conjunction with a safety evaluation module. This complies with the requirements for positive contact protection.

Closing the test cabin starts the test sequence. Opening the test cabin while the test is running will result in immediate cancel. The voltage released and the device under test discharge. Optionally, a safety lock can be installed to prevent opening during testing.

Complete insulation of the test room prevents voltage carryover to the outside. This provides optimum protection for operating personnel.

For an additional charge, test chambers made of ESD materials can be implemented to discharge sensitive test objects from electrostatic charge and discharge .

Test booths in various sizes and designs

High-voltage test cabin with swing door

Features of the test cabin

  • Ideal for large, bulky test objects
  • Front door for easy access and convenient handling
  • Maximum safety:
    • Protection of the operator against high voltages and dangerous currents
    • Dual-channel safety switches monitor the door
    • Optional: Door interlock for additional safety
  • Optimal contact protection guaranteed
  • Large viewing window:
    • Perfect observation during the examination
    • Additional safety clear visibility
  • Cable bushings:
    • Safe routing of test cables from the test device to the test cabin
    • custom as needed

High-voltage test cabin with hinged doors

Test booth for XXL test objects – Maximum safety comfort

  • Perfect for large and bulky test objects
  • Front door for convenient access – easy handling guaranteed
  • safety :
    • Protection against high voltages and dangerous currents
    • Dual-channel safety switches monitor the doors
    • Optional: Door interlock for extra safety
  • Optimal contact protection – uncompromising safety
  • Large viewing window:
    • Full control and perfect observation during the test
  • Externally mountable controls for controlling the test sequence
  • Flexible arrangement of cable entries:
    • Secure connection from the test device to the cabin
    • custom to your requirements

Your advantages Maximum safety, maximum flexibility, convenient handling.

High-voltage test cabin with roller door

Our flexibility – your advantage!

This example proves it:

  • Test booth with integrated blinds for perfect access, good visibility, and safety
  • Spacious area in front of the cabin for comfortable handling and easy operation

Customized solutions for your requirements – uncompromisingly secure and flexible.

> Request your desired configuration now!

High-voltage test cabin up to 50 kV

The electrically height-adjustable table shown is available as an option.

Test booth for extreme test voltages – ergonomics and safety

  • Ideal for device and material testing with very high TEST VOLTAGE
  • Ergonomic arrangement of all components on a lifting table for comfortable working
  • Secure connection:
    • Test device with high-voltage transformer high-voltage-resistant cables and bushings
  • Insulated high-voltage tube in the test cabin for convenient connection of the DUT
  • Grounding through metal lining:
    • Interior and door completely lined with conductive sheet metal
    • This forms the grounded counterpart to the high voltage.
  • Viewing window with protection:
    • Internal wire mesh or mesh braiding for additional safety
    • Good visibility of the DUT
  • Perfect sealing:
    • Contact tongues reliably close the gap between the door and the chamber.
  • Ideal for partial discharge testing
    • The effective shielding guarantees reliable EMC protection from external sources.
    • This is a prerequisite for reproducible partial discharge testing in
      • High voltage
      • Surge test

Your advantages: Maximum safety, ergonomic design, perfect for high-voltage and partial discharge tests.

All facts at a glance

Perfect touch protection

  • Mechanically robust and durable designs
  • Designed for tough use in industrial environments
  • Long service life and reliable operation
  • Safety door or rolling door
  • Ideal for large test objects
  • Accessible with pallet trucks
  • High-voltage test cabins
  • Integrated result lights
  • Space and solutions for terminals, contacts, and built-in components
  • Immediate interruption of the current test when opening
  • Up to performance level PL e
  • Dual-channel safety evaluation
  • Transparent test cover observing the test object during testing
  • options
    • automatic closing
    • automatic opening
    • Reinforcement for heavy-duty test specimens
    • ESD version
    • integrated lighting
  • solutions
    • for the installation of manual contacts/adapters
    • for the installation of automatic contacts/adapters

Downloads

Do you require personal product advice?

We would be happy to provide you with comprehensive support and advice regarding all our products and services.
Call us or send us an email!

  • Subscribe to SCHLEICH

    Our free newsletter—delivered directly to your inbox.

  • Fields marked with * are mandatory.

  • Contact form

  • Fields marked with * are mandatory.
  • Accepted file types: pdf, jpg, jpeg, Max. file size: 10 MB.
    • They are only uncompressed JPG/JPEG and PDF files allowed.
    • The maximum file size is 10 megabytes.