HandHeld

Protective conductor resistance and insulation resistance tester

The Handheld the ideal testing device for production and mobile use in the workshop and at the customer's site. And all this at a very attractive purchase price.

Typical applications include electrical safety inspections in production and service. Examples of use cases include hospital service on medical devices or testing lightning protection on wind turbine rotor blades.

Key facts:

  • protective earth conductor 10 A AC
  • TEST VOLTAGE 6 / 12 V
  • Evaluation criterion: protective conductor resistance
  • insulation resistance V DC
  • Test current current limited
  • Evaluation criterion: insulation resistance
  • Integrated test socket
  • Small, lightweight, and portable
  • Stop and test method selection on both sides for left- and right-handed users
  • Large result display
  • Internal test result memory time-delayed transfer of measured values to a PC

1 Product Variants

HandHeld

Test methods » PE · Iso
device typeground fault tester
insulation tester
Protective earth conductor10 A @ 6/12 V
Isolation1 kV / ≤30 MΩ
designdesk enclosure
Availabilityin 5 business days
order number 403001
Show all 1 product variants

The mobile specialist for safety inspections
Compact. Ergonomic. Robust.

The HandHeld is your specialist for standard-compliant protective earth conductor and insulation resistance tests. Thanks to its small, robust design, you can carry out safety tests not only efficiently in the workshop and production facility, but also flexibly on site—ideal for repairs, installation, and service calls at the customer's premises.

Robust technology for outdoor use

specialized mobile use, the entire testing technology is housed in an extremely robust, extruded aluminum casing.

data storage

Thanks to the integrated test result memory, there is no need to manually record the test results.

The measured values can be transferred to a PC via the serial interface, where they can be archived and printed out.

testing methods

test procedure Parameters & Advantages
protective conductor resistance Testing with 10 A AC using precise four-wire technology. The evaluation can be performed either via the resistance or the voltage drop.
insulation resistance The evaluation is performed either on the basis of resistance or current.
Extended insulation test The device the TEST VOLTAGE to be increased TEST VOLTAGE a maximum of 2,500 V DC. This is an interesting alternative to high voltage test alternating voltage (where 1,800 V ACeff corresponds to approximately 2,500 V DC).

Flexibility in contacting

There are two ways to contact the test object:

  1. The integrated test socket: This is used device under test the device under test . The tester uses the test tip manually test tip the individual test points in sequence.
  2. Alternatively, the protective earth conductor test object can be alligator clip via a connection cable with alligator clip . The tester uses the test tip manually test tip the individual test points in sequence.

Special application: Testing lightning conductors on wind turbines

For this purpose, the PE minimum current monitoring can be switched off, Test current measurements with reduced Test current . With a 50-meter-long measurement lead , four-wire technology up to 15 Ω measurement lead be measured using four-wire technology .

Accessories

Extensive Accessories carrying cases and shoulder straps facilitate mobile use and increase working comfort.

The controls and connections

Standard equipment

Function and technology

  • Manual test sequence
  • Built-in test result memory
  • Connection for test tip protective earth conductor or insulation resistance)
  • Connection for measurement lead alligator clips toConnection the test object.

Communication

  • 1 x RS232 on the rear panel
  • RS232 for Save test results a PC using the free SCHLEICH PrintCom 7
  • Test report printing with PrintCom 7

safety

  • protective conductor test: low, non-hazardous test voltage 
  • insulation test: Safety-limited, non-hazardous Test current
  • Special touch protection not necessary

The test protocol PrintCom

Free PC software for Save printing test results

PrintCom is the simple and efficient solution for Save test results Save printing test reports. The test results be archived inExcel® and printed out.

The PC software PrintCom is included with the test device. The test device has an integrated test result memory. This can be read out by PrintCom after each test or at a later time. PrintCom stores the test results the PC and allows a test report to be printed.

test results , display, and print test results .

Digital logging is easy with this software: it quickly transfers the test data via the serial interface and presents it in a clearly structured format on your PC. Print out the test protocol for your customers or Save as a PDF file to protect the environment.

Storage format of test results

PrintCom stores your test results directly inExcel® format. Benefit from maximum flexibility when creating reports.

  • The software already includes a wide selection of preconfiguredExcel® test report templates in various layouts.
  • Easy customization: Customize these templates directly inExcel® to suit your requirements. For example, add additional information or design the test protocol custom your company logo.
  • You can create completely new test protocol yourself inExcel® at any time.

online mode

In online mode, the testing device is permanently connected to a PC and PrintCom is running. As soon as a new test result after a test, it is immediately transferred to the PC and collected there. Once all tests have been completed, the collected results are saved.

offline mode

Alternatively, the testing device can test results the test results . This makes it possible to load the test results into PrintCom test results a later time and Save.

network

By configuring the storage path in PrintCom accordingly, theExcel® files can of course also be Save on the network.

All facts at a glance

Multifunctional tester for PE and insulation

  • Test current 10 A AC
  • Electronic test current setting with regulated current constancy
  • Insulation resistance test up to 1 kV DC
  • Electronic test voltage adjustment with regulated voltage stability
  • Easy to use
  • Stop button and test method selection on both sides for left- and right-handed users
  • Large result display
  • Automatic comparison with predefined limit values
  • Visual and audible alarm if test results outside the limit value
  • Internal test result memory time-delayed transfer of measured values to a PC
  • Includes PrintCom for Save printing test results a PC
  • Designed for comfortable transport
  • Small, lightweight, suitable for carry-on luggage on airplanes
  • Accessories mobile use such as carrying straps, outdoor transport cases, etc.
  • Standard device – available from stock
  • Includes traceable factory calibration certificate

The areas of application

Machinery Directive EN 60204

HandHeld checking compliance with the Machinery Directive on a system.

Lightning protection inspection on wind turbines

The robust testing device has proven itself in outdoor use thanks to its optimal carrying comfort and simple operation. The reliable conductivity of the lightning protection is measured from the tip of the rotor blade to the base of the tower.

Safety inspection in medical facilities

Typical application for testing the protective conductor and insulation on medical devices after repair or maintenance.

Downloads

Do you require personal product advice?

We would be happy to provide you with comprehensive support and advice regarding all our products and services.
Call us or send us an email!

  • Subscribe to SCHLEICH

    Our free newsletter—delivered directly to your inbox.

  • Fields marked with * are mandatory.

  • Contact form

  • Fields marked with * are mandatory.
  • Accepted file types: pdf, jpg, jpeg, Max. file size: 10 MB.
    • They are only uncompressed JPG/JPEG and PDF files allowed.
    • The maximum file size is 10 megabytes.