GLP2-BASIC 1420

Test methods » PE · Iso · Abl · Fkt
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
leakage currentSingle-phase
Function AC Single-phase12–260 Veff AC @ max. 5 A
Test pointFront test socket, country-specific
connection for test tip
test connection rear, 10-pin, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107021

GLP2-BASIC 1430

Test methods » PE · Iso · EAbl · Fkt
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
leakage currentSingle-phase (substitute leakage current)
Function AC Single-phase230 VRMS AC @ max. 16 A
Test pointFront test socket, country-specific
connection for test tip
test connection rear, 10-pin, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107022

GLP2-BASIC 1620

Test methods » PE · Insulation · HV AC · Leakage · Function
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High voltage AC6 kV @ 3 mA - safety current limited
leakage currentSingle-phase
Function AC Single-phase12–260 Veff AC @ max. 5 A
Test pointFront test socket, country-specific
connection for test tip
test connection rear, 10-pin, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107027

GLP2-BASIC 1630

Test methods » PE · Insulation · HV AC · Leakage · Function
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High voltage AC6 kV @ 100 mA
leakage currentSingle-phase
Function AC Single-phase12–260 Veff AC @ max. 5 A
Test pointtest connection rear, 10-pin
test tip connection box, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107028

GLP2-BASIC 1650

Test methods » PE · Insulation · HV AC · Equivalent Leakage · Function
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High voltage AC6 kV @ 100 mA
leakage currentSingle-phase
Function AC Single-phase230 VRMS AC @ max. 16 A
Test pointtest connection rear, 10-pin, optional
test tip connection box, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107030

GLP2-BASIC 1820

Test methods » PE · Insulation · HV DC · Leakage · Function
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High Voltage DC6 kV @ 4 mA
leakage currentSingle-phase
Function AC Single-phase12–260 Veff AC @ max. 5 A
Test pointFront test socket, country-specific
connection for test tip
test connection rear, 10-pin, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107033

GLP2-BASIC 1840

Test methods » PE · Insulation · HV DC · Equivalent Leakage · Function
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High Voltage DC6 kV @ 4 mA
leakage currentSingle-phase (substitute leakage current)
Function AC Single-phase230 VRMS AC @ max. 16 A
Test pointFront test socket, country-specific
connection for test tip
test connection rear, 10-pin, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107034

GLP2-BASIC 1930

Test Methods » PE · Iso · HV AC · HV DC · Leak · Fct
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High voltage AC6 kV @ 100 mA
High Voltage DC6 kV @ 4 mA
leakage currentSingle-phase
Function AC Single-phase12–260 Veff AC @ max. 5 A
Test pointFront test socket, country-specific
test connection rear, 10-pin, optional
test tip connection box, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107036

GLP2-BASIC 1940

Test methods » PE · Insulation · HV AC · HV DC · Equivalent Leakage · Function
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High voltage AC6 kV @ 3 mA - safety current limited
High Voltage DC6 kV @ 4 mA
leakage currentSingle-phase (substitute leakage current)
Function AC Single-phase230 VRMS AC @ max. 16 A
Test pointFront test socket, country-specific
connection for test tip
test connection rear, 10-pin, optional
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107037

GLP2-BASIC 1950

Test methods » PE · Insulation · HV AC · HV DC · Equivalent Leakage · Function
Device typeSafety & Function Test Device
protective earth conductor30 A @ 6/12 V
Insulation1 kV / ≤10 GΩ
High voltage AC6 kV @ 100 mA
High Voltage DC6 kV @ 4 mA
leakage currentSingle-phase (substitute leakage current)
Function AC Single-phase230 VRMS AC @ max. 16 A
Test pointsL1, N, PE, test tip
Test pointtest connection rear, 10-pin
Safety concept2-channel
Design19" enclosure, 4- HM s • optionally available with a mounting kit for a 19" rack
Availabilityin 5 working days
Order number 40107038
No testing device found? – No problem!

We configure your modular solution – ask us.

  • Subscribe to SCHLEICH Newsletter

    Our free newsletter - directly in your mailbox.

  • Fields marked with * are mandatory.

"*" indicates required fields

Contact Form

Fields marked with * are mandatory.
Accepted file types: pdf, jpg, jpeg, Max. file size: 10 MB.
  • Only uncompressed JPG/JPEG and PDF files are allowed.
  • The maximum file size is 10 MB.
Data protection*