Opens in a new tab

Know How

SCPI communication

SCPI

Brief Information on SCPI Commands

In 1975, IEEE standardized the GPIB (General Purpose Interface Bus) developed by Hewlett-Packard as IEEE-488.

In 1990, the SCPI Consortium published the first SCPI standard (Standard Commandsfor Programmable Instruments). Combined with the IEEE 488.2 standard, which defined the " protocol" and message formats, this created a unified software interface for cross-vendor communication with programmable measurement and test equipment.

See also: http://en.wikipedia.org/wiki/Standard_Commands_for_Programmable_Instrumentation

See also: SCPI 1999.0

SCPI allows you to communicate directly with the test equipment. This can be done, for example, via an external PC, a control computer, or a PLC.

On the PC, remote control software developed by operator is used for this purpose; it is used to exchange data, actions, and status information with the test device. Alternatively, common development and test environments such as LabVIEW can also be used.

Since SCPI is a globally established standard, the structure of the commands is clearly defined. As a result, the design and implementation of the communication routines are logical, straightforward, and can be quickly implemented by the operator .

SCPI provides you with a clear economic advantage: Thanks to the standardized command structure, you can implement remote control quickly, efficiently, and purposefully.

The commands can be written in both uppercase and lowercase letters; in principle, the spelling is not case-sensitive.

As specified in the standard, the uppercase letters of a command are mandatory in the following examples. The lowercase letters are optional. This allows commands to be either abbreviated to a minimal short form or fully written out for better readability.

Examples of some of the approximately 50 available commands:

 

PROGram:CATalog? – Returns the test plan currently active in the test device.

PROGram:SELected:EXECute – Starts the test according to the currently loaded test plan.

PROGram:SELected:STATe – Controlsthe start or " cancel " of the currently loaded test plan (RUN | STOP).

PROGram:SELected:STATe? – Queries the status of the currently loaded test plan. The test device returns one of the following status values:
– RUN – The test program is currently running.
– STOP – The test program has been stopped.
– CHANGING – The test plan’s status is currently being changed.
– PROGRAM_ENVIRONMENT – The device is in programming or editing mode.

MMEMory:LOAD TestplanNameXY – Loads a test plan stored in the test device or network for further use.

Test devices and Test systems

GLP2-BASIC

protective earth conductor-, Insulation, High-Voltage, leakage current, Resistance, and Functional Testers

  • Insulation test devices
  • High voltage test devices AC/DC
  • “All in one” test devices
  • Safety & functional test devices
  • Approx. 40 device variants – combined from up to 21 test methods
  • PL e, SIL 3, two-hand control Type III C, Cat. 4 safety circuit (depending on device variant and degree of hazard)
  • Network
  • protocol- & Label Printing
  • Scanner …
  • Technology Package for even greater ergonomics
  • desktop device or 19-inch rack mounting

View product 

GLP2-BASIC leakage current test devices

12 Device Variants

  • Industrial and medical leakage current test
  • leakage current test including function test
  • Single-phase 1/N/PE AC
  • + optional protective conductor resistance, insulation resistance, high voltage
  • Communication with PCs, PLC,LabVIEW®, MES/ERP
  • Fieldbus e.g. PROFIBUS …
  • Industrial Ethernet e.g. PROFINET, EtherCAT, EtherNet/IP, Modbus-TCP …
  • Ideal for
    – manual testing
    – fully automated test stations, EOL …
    – testing in a test cover, test booth, production line …
    – OEMs, equipment manufacturers

View product 

GLP2-BASIC high voltage test devices

8 Device Variants

  • AC 6 kV | 3, 100 mA
  • DC 6 kV | 6, 100 mA
  • Insulation 1 kV, ≤10 GΩ

Ideal for

  • Manual tests with high voltage test probes
  • Testing in an test cover test booth
  • Fully automatic test stations
  • OEMs, systems engineering
  • Communication with PCs, PLC,LabVIEW®, MES/ERP
  • Fieldbus e.g. PROFIBUS …
  • Industrial Ethernet e.g. PROFINET, EtherCAT, EtherNet/IP, Modbus-TCP …

View product 

GLP2-MODULAR

Multifunction test device with up to 25 test methods

  • “All in one”
  • Safety test devices
  • Safety & functional test devices
  • Modularly combinable from over 25 test methods
  • Up to 250 test connections
  • Switching matrixes for all types of test methods
  • PL e, SIL 3, two-hand control Type III C, Cat. 4 safety circuit (depending on device variant and degree of hazard)
  • Network
  • protocol- & Label Printing
  • Scanner …
  • Technology Package for even greater ergonomics

View product 

GLP2-MODULAR high voltage test devices

  • AC 6 – 100 kV, 3 – 5000 mA
  • DC 4 – 100 kV, 6 – 1000 mA
  • Insulation 1 – 10 kV, ≤500 GΩ

Ideal for

  • Manual tests with high voltage test probes
  • Testing in an test cover test booth
  • Fully automatic test stations
  • OEMs, systems engineering
  • Communication with PCs, PLC,LabVIEW®, MES/ERP
  • Fieldbus e.g. PROFIBUS …
  • Industrial Ethernet e.g. PROFINET, EtherCAT, EtherNet/IP, Modbus-TCP …

View product 

GLP2-BT

High-voltage storage testing device - Traction Battery Tester

  • “All in one”
  • High-voltage storage safety testing device
  • Modularly combinable from various test methods
  • Up to 400 test connections
  • Switching matrixes for all types of test methods and applications
  • PL e, SIL 3, Cat. 4 safety circuit (depending on device variant and hazard level)
  • Network
  • PLC-Communication
  • Technology Package for even greater ergonomics and even more possibilities

View product 

GLP2-R

For EOL testing
For fast automation processes and inline quality assurance
For laboratories and manual measurements

  • Four-wire technology, eliminates line and contact resistances
  • Measurement cable break detection
  • Contacting error detector
  • Temperature compensation for temperature-dependent resistances
  • Surface or ambient temperature measurement
  • Automatically executing test steps
  • Integrated switch-over between different checkpoints
  • Test points modularly expandable with relay matrices

Communication with
«» PC
«» PLC
«» LabVIEW®
«» MES / ERP
«» Fieldbus, e.g., PROFIBUS …
«» Industrial Ethernet, e.g., PROFINET, EtherCAT, EtherNet/IP, Modbus-TCP …

View product 

GLP2-Technology Package

GLP2 meets Windows 11®

  • Maximum Windows 11® performance for GLP2
  • Performance upgrade for GLP2-BASIC and GLP2-MODULAR
  • Full-fledged Windows 11® on external PC
  • Maximum ease of use
  • Intuitive user guidance
  • Optimized visualization and faster inputs
  • built-in s seamlessly into your IT environment
  • Plug-and-play integration into the company network

View product 

"*" indicates required fields

Form

Request Detailed Information - The SCHLEICH test method handbook

Fields marked with * are mandatory.
Data protection*

  • Subscribe to SCHLEICH Newsletter

    Our free newsletter - directly in your mailbox.

  • Fields marked with * are mandatory.

"*" indicates required fields

Contact Form

Fields marked with * are mandatory.
Accepted file types: pdf, jpg, jpeg, Max. file size: 10 MB.
  • Only uncompressed JPG/JPEG and PDF files are allowed.
  • The maximum file size is 10 MB.
Data protection*