Know How
armature booster

An additional armature booster is available for the MTC2 testers in accordance with the " armature test " standard. The armature booster is required for testing larger, low-inductance DC armatures. It increases the inrush current tenfold, making it easier to detect short circuits and insulation faults.
The evaluation is performed automatically using SCHLEICH's patented method.
The MTC2's test leads are plugged into the armature booster . On the output of the booster, the operator has access to two sturdy test probes with built-in start buttons. In addition, a built-in warning light indicates whether the terminals are de-energized or being tested.
The test is performed with two test probes pressed onto the bars (bar method). The test thus takes place between two bars of the commutator. You initiate the test via the two start buttons on the test probes.

Using the bar spacing you selected for the test, you now perform one test after another. This is repeated until you have scanned all bars around the commutator.
Instead of using test probes, you can conveniently use an anchor adapter to Test. The spacing between the test probes can be adjusted to match the spacing of the fins.

The test is evaluated using a fully automated test sequence, which guides the operator through the measurement process. Alternatively, you can also perform tests without a fixed sequence of test steps. With both methods, the MTC2 performs a pulse waveform comparison with a previously stored reference.

Test devices and Test systems
MTC2 R7
Universal winding Test devices 6, 12, 15, 30, 40 and 50 kV
MTC2 winding Test systems are very compact, fully automatic high-end Test devices for a wide variety of winding goods in development, production, and Test laboratory.
For production, EOL, automation
For test laboratory, R&D, approval, certification tests
For repair, maintenance, and service
surge test
-
- Ultra-fast 50 measurements per second
- Phase comparison between phases
- Patented peak-to-peak measurement
Partial discharge compliant with DIN EN 60034-18:2014
-
- Passive or active antenna
- Conducted coupling
ohmic resistance
-
- Winding
- Temperature sensor
insulation resistance
-
- IR
- PI
- DAR
High voltage AC optional
Test connections
-
- Standard: 4
- Optional: 7 and more
"*" indicates required fields