Based on its modular concept, this tester can be configured for a great variety of voltage levels and voltage types. The voltage necessary for your testing task is selected from a large pool of HV test methods. Whether only one AC test method or a combination of AC and DC - the configuration of the tester is defined by you! Depending on the testing task the GLP2-e/i can, for example, also be equipped with a matrix (switching unit). With the flexible concept of the GLP2-i, it is possible to compose a tester that meets your requirements ideally. It is not necessary to install individual testing devices for every required test method into a large service cabinet. All test methods can be integrated into an extremely compact testing device with a height of 4, 6 or 9HE (height modules). This flexibility is your price benefit. This is what we call "customer-based technology". The testers can also be delivered with test covers. Highlights | Product Features | automatic switch-over between the test methods - standard for more than 15 years! | large LCD graphics display with 256*128 pixel and touch screen | test program database and result storage | optical and acoustical error message when exceeding limit values | freely programmable additional processes for outputs and inputs | integrated statistics | | single tests with large display | extremely short testing periods save a lot of time | 2 * RS232 for printer or remote control | completely remote-controllable via RS232 interface | standard PC printer connection (lpt - Centronix- parallel) | thermal transfer printer for label print-out | standard PC-keyboard connection / connection for barcode reader | CAN-bus connection | 16...80 freely programmable outputs and 4...68 freely programmable inputs | WINDOWS® software for remote control, for the administration of databases for test programs and test results and for printing-out test protocols | network (wired or wireless) with testing devices and a central PC with NetCom Xi | optimum pre-conditions for OEM applications / integration into automatic lines | 19" installations accessories | extensive accessories like test covers, contactings, adapters, ... | You can count on our experience from thousands of testers used world-wide! |

Product DescriptionThe new generation of the GLP2 comes with an optimized technology and an attractive appearance. A special highlight is the innovative operation via touch screen in combination with a large graphics display. The tester is operated only by touching the symbols on the graphics display. Numbers and letters can be entered, too. In addition, it is, of course, also possible to connect a standard PC-keyboard and/or a barcode scanner. The GLP2-e | GLP2-i has a test program database for more than 200 test programs and a result database. The results can be stored, transmitted to a PC or printed out. Directly after testing, you can print labels on a thermal transfer printer and attach them to your products. This way you can be sure that the products you bring into the market are tested and safe. Depending on the configuration and the composition, the type of the tester will be either the extremely compact GLP2-e or, alternatively, the larger GLP2-i. As for the operating features of the tester and the performance of software and interfaces, both types are completely identical. High-voltage testers with an automatic high-voltage adjustment can also perform freely programmable voltage profiles.   
       

Test Methods
Test | Data | | | | up to 100KVAC | with active-current evaluation | | optional: with ARC detection |
| | | | up to 100KV DC | | up to 100KV single-way rectification | | up to 50KV with bridge recitfication | | up to 40KV via highly stable cascades with the lowest residual ripple |
| | | | visual examination of the test object by the operator |
|


Transformer Types | Types | Devices | 
| Type A In order to have the necessary distance to the ground, this vertical tube is used for high voltages. Send us your inquiry: We will find a suitable solution.
| 
| Type B The diagonal tube type can be used for all voltages. This type has the optimum distance to the ground and normally offers an optimum connection of the high voltage. Send us your inquiry: We will find a suitable solution.
|  | Type C The horizontal tube type is used for low voltages, because otherwise the distance to the ground could not be kept. Unless the transformer would be installed on a base, etc. Send us your inquiry: We will find a suitable solution.
|
Product Overview | Photo | Devices | 

| article number | 40105046 | 40105047 | 40105048 | 40105049 | | test voltage | 3000V | 6000V | 3000V | 6000V | | Imax | 100mA | 100mA | 100mA | 100mA | | Ik | 200mA | 200mA | 200mA | 200mA | | man. high-voltage adjustment | 
| 
| 
| 
| | auto. high-voltage adjustment | | | 
| 
| | test time | 0.1s ... 200h | 0.1s ... 200h | 0.1s ... 200h | 0.1s ... 200h |
Electrical type overview | 700VA | 1,25KVA | 3KVA | 5,5KVA | 8,5KVA | 15KVA | 20KVA | | 10 KV | 
| 
| 
| 
| 
| 
| 
| | 15 KV | 
| 
| 
| 
| 
| 
| 
| | 20 KV | 
| 
| 
| 
| 
| 
| 
| 25 KV | 
| 
| 
| 
| 
| 
| 
| | 30 KV | 
| 
| 
| 
| 
| 
| 
| | 35 KV | 
| 
| 
| 
| 
| 
| 
| | 40 KV | 
| 
| 
| 
| 
| 
| 
| | 50 KV | 
| 
| 
| 
| 
| 
| 
| | 60 KV | 
| 
| 
| 
| 
| 
| 
| | 70 KV | 
| 
| 
| 
| 
| 
| 
| | 80 KV | 
| 
| 
| 
| 
| 
| 
| | 100 KV | 
| 
| 
| 
| 
| 
| 
|
Any other voltages and currents are possible without problems. | | The maximum voltage is 100KV. | Depending on the voltage, the maximum test current has several Ampere. | | Testers over 6000V are delivered exactly accoring to your specifications. | Send us your inquiry: We have the ideal solution for you. | | 

| - 6KV @ 3mA | grounded or floating
- 6KV @ 5mA | grounded or floating
- 6KV @ 10mA | grounded or floating
- 6KV @ 20mA | grounded or floating
- 6KV @ 40mA | grounded or floating
- 10KV @ 3mA | grounded
- 15KV @ 2mA | grounded
- 20KV @ 1,5mA | grounded
- 30KV @ 1mA | grounded
- 40KV @ 0,75mA | grounded
Other voltages and currents available on request. | | The maximum test voltage is 100KV. | Depending on the voltage, the maximum test current has several Ampere. | Send us your inquiry: We have the ideal solution for you. |
|

Interfaces remote control of the testing device via a PCremote control of the testing device via a PLCanalog output [option]analog input [option]data input via standard PC keyboard and/or barcode scannerdata output via serial or parallel PC printers or via thermal transfer printersFor communicating with the electronic environment, the tester is equipped with two serial interfaces. It is possible to print or, alternatively, remote-control the tester via a PC with our software NetComXi or PrintCom. A test step generated in NetCom is transmitted to the tester, where it is performed and the result is returned to the PC. NetCom stores the result on the PC. This is the ultimate solution, because you have a test system, which documents and logs all test steps. In addition, it is possible to operate several testers in one network with a central PC. Test programs can be transmitted to the testers and the test results can be returned to the PC, where they are stored. The complete data exchange is controlled via our PC software NetComXi. For details, please refer to "NetComXi" or "PrintCom". Of course, you can also use your own software to remote-control the tester. The tester can be remote-controlled with Agilent VEE® or LabVIEW®. For LabVIEW®, a high-performance driver is available. 
Technical Data | Supply | mains voltage | 230VAC +-10% | other voltages optionally | frequency | 49Hz / 61Hz | | fuse protection | depending on the configuration of the tester |
General Information | languages | German, English, Italian | programming | free programming of all parameters | remote control | digital | yes | via 24VDC inputs/outputs | RS232 | 2 interfaces | start test | front switch, foot switch, start signal out of the test pistol | | safety | key switch for HV | | safety test pistols | | Emergency-Stop Contact | protection-cover safety contact for limit switches | | display | graphical display with touch panel | | storage of test programs | for up to 256 test programs | | result storage | for up to 256 results | | dimensions GLP2-e | 236 * 320 * 178 mm (W*D*H) | | dimensions GLP2-i | 236 * 320 * 178 mm (W*D*H) | | weight | depending on the configuration of the device | | color GLP2-e | side panels RAL7035 / top RAL 7035 | | operating temperature | 10 degrees ... 50 degrees Celsius | | storing temperature | -20 degrees ... 60 degrees Celsius | | calibration | incl. calibration certificate |
Features| Feature | graphics LCD | | The graphics LCD allows an optimum overview as well as a safe and intuitive operation. | | | | Feature | inputs via Touch Panel | | Only this tester offers this unique feature. The device is operated by simply touching the display with the finger. The operation is, therefore, extremely simple, fast and save. You can find this type of operation more and more often in public life, e.g. at cash desks or in airport terminals. A protective coating makes sure that the display doesn’t get damaged or soiled by touching it. In addition, it guarantees a reliable functionning. | | | | Feature | HV adjustment of release current and output voltage at no-load | | This option offers an easy and safe way to adjust release currents and output voltages, because the parameters are adjusted without activated high voltage. | | | | Feature | automatic storage of the setting values in the tester | | After switching on the mains voltage, in order to avoid operating errors, the device boots with the parameters and the test program of the preceding test. | | | | Feature | adjustment of all parameters via comfortable menu navigation | | The comfortable menus make sure that the operator can adjust all test parameters directly at the tester. | | | | Feature | help keys in the setup menus | | For every setting value, the display has a help key, which activates the detailed help-text display. | | | | Feature | access-safe tester | | The release / the switching on of the high voltage is secured via a key switch. | | | | Feature | access-safe control | | Inputs can be disabled via a password. | | | | Feature | mains and load regulation with automatic voltage adjustment | | In order to make sure that the test results are constant and correspond to the safety requirements, the tester keeps the output voltage constant from no-load to full load and over the mains voltage range within the setting limits. | | | | Feature | electronic test times | | By making sure that the duration of the test is the same for every tested product, the electronic test times enable constant test results. | | | | Feature | display of test parameters and test results via LCD at the front panel | | The operator can monitor the test via an LCD at the front panel. After a test object has been tested, the result remains visible on the LCD, so that the operator can easily view the test results. | | | | Feature | combination tester | | This device can be equipped with a great variety of test methods. Dieses Gerät lässt sich mit den unterschiedlichsten Prüfmethoden bei gleicher Gerätegröße ausstatten. Dies hat den Vorteil, dass der Tester trotz alle Prüfmethoden sehr kompakten und handlich bleibt. | | | | Feature | automatic switch-over between low-voltage test and high-voltage test | | For many years now, our compact testers have been equipped with an automatic switch-over between the test methods, if desired. This way, the operator needs to connect the test object only once and all tests can be performed one after the other without having to reconnect the test object. This is quickest and most reliable solution. | | | | Feature | calibration solely via the software | | The complete calibration is performed via the software. It is not necessary to open the device. Thus, there is no danger that the technician touches the high voltage. | | | | Feature | built-in safety devices | | The connection of safety contacts and an Emergency Stop allow to connect a safety device for the high-voltage protection of the operator. | | | | Feature | PC software: PrintCom | | This software allows easy reading in of test results, storage in an EXCEL® file and comfortable printing of self-generated test programs. | | | | Feature | PC software: NetCom | | With this software the tester can be remote-controlled completely. All test programs and test results are stored in a central ACCESS® database. Test programs can be transmitted to the tester. The test results can be printed and statistically evaluated in many different ways. | | | | Feature | PC software: NetCom network | | This software allows the complete remote control of up to 32 testers in a network. The network can be generated via RS485 connections. As an alternative, it is possible to operate up to 32 testers in an Ethernet computer network. This way, you can use your standard PC network without extra cabling. |

Applications / Screens 
| 
| | GLP2-i 65KV | GLPe-2 in rolling container with matrix 12KV | 
| 
| | tester for electronic modules 25KV | tester for electronic modules 25KV | 
| | | tester for material testing 45KV | | 
| 
| | large display of HV test | large display of HV test |

 | Safety Barriers Safety barriers serve to prevent access to test areas according to standards. The chains are supposed to preve....
more |
 | Test Covers - single Test covers serve for the protection of the operator and prevent that the test object is touched during the te....
more |
 | Label Printers The label printer is used in order to print labels automatically after the test. The layout of the label is de....
more |
 | Foot switch The foot switch can be used for starting a test. Depending on the configuration of a tester, the foot switch m....
more |
 | High-voltage cable We supply high-voltage cables for voltages up to 100KV with individual cross sections and in varying designs.....
more |
 | High-voltage plugs We supply a great variety of high-voltage plugs. With these components you can, for example, build your own sw....
more |
 | High-voltage test pistol The test pistol is used for contacting the test object during the manual high-voltage test. Various high-volta....
more |
 | Warning Lamps Warning lamps serve to indicate, whether a test object is connected to voltage or not. ....
more |
 | Two-Hand Start For testers with a functional test or a high-voltage test without test cover, we strongly recommend to us a tw....
more |
 | GLP1-e - HIPOT TESTER High voltage testing devices from the GLP1-e family serve for testing insulation capability and electric stren....
more |
 | NetCom Xi NetCom Xi is our answer to modern data management of test programs and test results. NetCom Xi is a Windows® s....
more |
 | PrintCom PrintCom is the easiest and most efficient solution for storing test results and printing test protocols. ....
more |
|