Highlights | Product Features | universal testing device for electronic products and lamps | lamp tester | combination tester with manual procedure of the test methods (PE + ISO + CNT + function) | 2-line, 16-digit, well readable blue LCD | comfortable operation and adjustment | PE resistance test with 10A (30A) AC in 4-wire configuration / evaluation on resistance or voltage drop | insulation resistance test / evaluation on insulation resistance or current | lamp tester with switchover for protection class I / II | optional with high-voltage test incl. safety current limitation to 3mA | either 1500V AC constant or switchable via the protection class switch 1500V/4000V AC constants | short-circuit test before the functional test | continuity test with evaluation of the minimum and maximum contact resistance | secured functional test with current measurement and evaluation | functional test via integrable isolating transformer | functional test with up to 3 currents for products with up to 3 different current circuits | ideal for lamp testing | acoustic error message and optical signal at the device and via "signal lamps" | indication of the type of error in clear text | continuity test via measuring leads for testing connections | adjustment of the language and various other functions of the tester directly via the input keys (no PC necessary for the configuration) | connections for Emergency Stop, safety contact and warning lamp | RS232 for printer or remote control | remote-control mode / completely remote-controllable via RS232 interface | remote-control mode / completely remote-controllable via digital inputs and outputs | easy-to-operate menu for adjusting limit values, times, etc. | self-test via black box according to VDE | WINDOWS® software for remote control, for the administration of databases for test programs and test results and for printing-out test protocols | network (wired or wireless) with testing devices and a central PC with NetCom Xi | I/O interface and analog control inputs and actual value outputs | 19" installation material |

Product DescriptionWith the necessary minimum of setting parameters, the GLP1-e L has been designed for standard test processes. If more complex test processes and more test methods are required, we are looking at testers from our GLP2 family. The front panel of the tester has an earthed socket where you can connect the test object. Four additional 4mm safety laboratory sockets (L/N/PE1+PE1-Sense / parallel to the earthed socket) allow the connection of mains adaptors with banana plug. Laboratory measuring leads can be connected here, as well. In addition, a connection socket for the PE test probe is installed at the front panel. Two additional 4mm safety laboratory sockets (PE2+PE2-Sense / parallel to the connection socket) allow the connection of laboratory measuring leads. In order to ensure a precise measurement, the measurement is consistently performed in 4-wire configuration all the way to the PE test probe. Complicated balancing to the PE test are therefore not necessary. The PE test probe is also used for testing the insulation capability at electrical goods of protection class II. With the test probe, electrically conductive parts are tested for their insulation against the current-carrying leads (L+N). For an even more convenient operation, a test probe with integrated start switch is available. A test process starts with the PE test and the insulation resistance test, which can take place at the same time. For this purpose, between the PE supply terminal and the test probe, the ground continuity is detected in 4-wire configuration. If various PE points are to be tested, the operator contacts the points one after the other. In order to obtain an optimum process speed, the PE test process can start itself immediately by touching the test object. After the safety tests have been completed, the testing device checks automatically, whether the resistance between L and N is too low. If there is no short circuit, the function test follows immediately. It can be done with our without evaluation of the current. All these advantages offer a very high test safety. With the monitoring functions that can be activated, it is possible, even for untrained personnel, to perform the tests safely and reliably. The integrated minicomputer allows functional operation and programming. The test parameters of the individual tests can be adapted to the testing task. The blackbox test, required by VDE, is integrated, as well. 
Test Methods
Test | Data | | | | 0 ... 0.7Ω / 10A AC electronic constant-current source / max. 12V |
| | | insulation resistance test |
| | 0 ... 30MΩ / 100 ... 1000V DC / max. 4mA |
| | | | 1500VAC or 1500VAC/4000VAC | max. 3mA |
| | | | test before the functional test, whether the test object has no short-circuit |
| | | functional test / current consumption |
| | 0.001 ... 5A / 1-phase / 230V fixed voltage directly from the mains or via isolating transformer |
|

Product Overview | Photo | Devices | 
| article number | 401851 | 401868 | | ground-continuity test | 10A | 10A/25A | | measuring range | 0 ... 0.7Ω | 0 ... 0.7Ω | | resolution | 0.001Ω | 0.001Ω | | max. voltage | <12V | <12V | | test time | 0.1 ... 10s | 0.1 ... 10s |
| 
| article number | 401852 | | insulation-resistance test | 100 ... 1000V | | measuring range | 0.2 ... 30MΩ | | resolution | 10KΩ / 100KΩ | | max. current | <3mA | | test time | 0.1 ... 600s |
|  | article number | 401865 | 4018113 | 4018105 | 4018112 | | ground-continuity test | 10A | 10A | 10A/25A | 10A/25A | | measuring range | 0 ... 0.7Ω | 0 ... 0.7Ω | 0 ... 0.7Ω | 0 ... 0.7Ω | | resolution | 0.001Ω | 0.001Ω | 0.001Ω | 0.001Ω | | max. voltage | <12V | <12V | <12V | <12V | | test time | 0.1 ... 10s | 0.1 ... 10s | 0.1 ... 10s | 0.1 ... 10s | | insulation-resistance test | 100 ... 1000V | 100 ... 2600V | 100 ... 1000V | 100 ... 2600V | | measuring range | 0.2 ... 30MΩ | 0.2 ... 30MΩ | 0.2 ... 30MΩ | 0.2 ... 30MΩ | | resolution | 10KΩ/100KΩ | 10KΩ/100KΩ | 10KΩ/100KΩ | 10KΩ/100KΩ | | max. current | <3mA | <3mA | <3mA | <3mA | | test time | 0.1 ... 600s | 0.1 ... 600s | 0.1 ... 600s | 0.1 ... 600s |
| 
| article number | 40185015 | 40185020 | | ground-continuity test | 10A | 10A | | insulation-resistance test | 100 ... 1000V | 100 ... 1000V | | short-circuit test between L+N | 
| 
| | functional test at mains voltage | 2A | 5A |
|  | article number | 40185026 | 40185027 | | ground-continuity test | 10A | 10A | | insulation-resistance test | 100 ... 1000V | 100 ... 1000V | | short-circuit test between L+N | 
| 
| | functional test at mains voltage | 2A | 5A | | high-voltage test AC | 1500V | 1500V |
|  | PE + IR + FCT + HV 1500V/4000V |
article number | 40185021 | 40185022 | | ground-continuity test | 10A | 10A | | insulation-resistance test | 100 ... 1000V | 100 ... 1000V | short-circuit test between L+N | 
| 
| | functional test at mains voltage | 2A | 5A | | high-voltage test AC | 1500V/4000V | 1500V/4000V |
At this device, a high-voltage test pistol is used as test probe. |

Interfaces

| RS232 | 
| PLC | 
| PC | | | 
| printer | 
| printer | 
| warning lamp | 
| result lamp | 
| foot switch | 
| Analog Out | | | | | RS232 for remote control of the testing device via a PC RS232 for printing test protocols (ASCII format) RS232 for remote control of the testing device via a PLCdigital inputs for connecting a foot switch, an external start switch or a control paneldigital inputs for remote control of the testing device via a PLCdigital outputs for the indication of the test result via a result lampdigital outputs for the indication of the state of risk via a warning lampdigital outputs for the indication of the condition of the deviceanalog output [optional]For communicating with the electronic environment, the tester is equipped with a serial interface. It is possible to print or, alternatively, remote-control the tester via a PC with our software NetComXi or PrintCom. A test step generated in NetCom is transmitted to the tester, where it is performed and the result is returned to the PC. NetCom stores the result on the PC. This is the ultimate solution, because you have a test system, which documents and logs all test steps. In addition, it is possible to operate all testers of the following families in one network with a central PC: Handheld, GLP1 and GLP2. Test programs can be transmitted to the testers and the test results can be returned to the PC, where they are stored. The complete data exchange is controlled via our PC software NetComXi. For details, please refer to "NetComXi" or "PrintCom". A remote control via Agilent VEE® or LabVIEW® is possible without problems. For LabVIEW® a high-performance driver is available.
Technical Data Supply | mains voltage | 230VAC +-10% | frequency | 49Hz / 61Hz | fuse protection | 10 Amp |
General Information | language of the software | German, English, Italian / selectable at the tester | programming | free programming of all parameters directly at the tester | remote control | digital | yes | belongs to the basic delivery extent | RS232 | yes | belongs to the basic delivery extent | | analog | yes - optional | start test | front switch, foot switch, start switch in the test probe, digital input | | safety | key switch for HV | | safety test pistols | Emergency-Stop contact | protection-cover safety contact for limit switches | | display | 2 * 16-line high-contrast display blue/white | | result storage | up to 128 results / optional 1024 results | | enclosure | solid and robust industrial aluminum enclosure | | dimensions | 236 * 320 * 178 mm (W*D*H) | | weight | 16kg | | color | side panels RAL7035 / top RAL 7035 | | operating temperature | 10 degrees ... 50 degrees Celsius | | storing temperature | -20 degrees ... 60 degrees Celsius | | calibration | incl. calibration certificate |
Output Data | Functional Test | voltage | 230V from the mains or via isolating transformer | current | max. 5A (2A) | | frequency of the voltage | 50Hz / 60Hz (depending on the mains) 50Hz / 60Hz (depending on the mains) |
General Information | Functional Test | current measurement | yes | evaluation | with GO/NO GO evaluation of the current | voltage measurement | no | | Imax maximum current limit | range | 0.01 ... 5 A (2A) | | resolution | 0.01A | | accuracy | +- 2% of setting value +- 0.01A | | Imin minimum current limit | range | 0.01 ... 5 A (2A) | | resolution | 0.01A | | accuracy | +- 2% of setting value +- 0.01A | | test time | adjustable | 0 ... 10.0 s | resolution | 0.1 s | accuracy | +- 0.1% of setting value +0.05s |
High-Voltage Test Output Data | voltage | 1500V AC or 1500V/4000V | current | max. 3mA AC | | frequency of the voltage | 50Hz / 60Hz (depending on the mains) |
General Information | test method | true r.m.s. measurement | evaluation | with GO/NO GO evaluation of the current | | test type protection class I | L+N against the PE of the test socket | | test type protection class II | L+N against the test probe | | test probe 1500V | test probe for PE, IR and HV | | test probe 1500V / 4000V | test pistol with integrated start pushbutton for PE, IR and HV | | fault signal | optical and acoustical | | test time | adjustable | 0 ... 10.0s | resolution | 0.1s | accuracy | +- 0.1% of setting value + 0.05s |
Ground-Continuity Test Output Data | voltage | max. 12V AC | current | min. 10A AC | regulation | automatic constant-current regulation | | frequency of the voltage | 50Hz / 60Hz (depending on the mains) |
Rmax (maximum PE resistance) | range | 0.01 ... 0.7W | resolution | 0.01W | accuracy | +- 2% of measured value +- 0.01W |
General Information | test method | 4-wire resistance measurement / Kelvin measurement | evaluation | with GO/NO GO evaluation | limit-value evaluation | max. resistance or max. voltage drop | | test type | test probe against the PE of the test object | | test probe | light test probe with removable test prod | up to the test probe in 4-wire configuration | | with integrated start switch (option) | | fault signal | optical and acoustical | | test time | adjustable | 0 ... 10.0s | | resolution | 0.1s | | accuracy | +- 0.1% of setting value + 0.05s |
Insulation Test Output Data | voltage | 100V DC ... 1000V DC | current | max. 4mA DC | regulation | automatic constant-current regulation | | accuracy | +- 10V | setting step size | 10V |
Rmin (minimum IR resistance) | range | 0.05 ... 30MW | resolution | 10KW | accuracy | +- 2% of measured value +- 10KW |
Features| Feature | solid aluminum metal enclosure | | The tester has a solid industrial design. For industrial applications, instable plastic enclosures have major disadvantages. Especially in the rough day-to-day production, high-voltage testers must have a great stability and long-term safety. |
| Feature | automatic storage of the setting values in the tester | | After switching on the mains voltage, in order to avoid operating errors, the device boots with the parameters and the test program of the preceding test. |
| Feature | adjustment of all parameters via comfortable menu navigation | | The comfortable menus make sure that the operator can adjust all test parameters directly at the tester. An external PC for the configuration of the tester is not necessary! |
| Feature | electronic test time | | The electronic test time ensures that the test time remains the same for every tested product, which enables constant test results. |
| Feature | Anzeige von Prüfparametern und Prüfergebnissen über LCD | | Über eine LCD kann der Bediener die Prüfung beobachten. Nach dem Test eines Prüfobjektes bleibt das Ergebnis auf der LCD sichtbar, damit sich der Bediener die Prüfergebnisse bequem ansehen kann. |
| Feature | display of test steps and individual test results via LED lamps | | Various LED lamps (red, yellow, green) serve for indicating the status of the test step. Every test method has its own LED lamp. |
| Feature | test probe for PE test and insulation-resistance test | | The PE and the insulation to the enclosure of the test object are tested with one test probe. For this purpose, the enclosure of the test object is connected to the tester via a ground lead. This allows fast and safe testing. |
| Feature | electronic PE current regulation | | The electronic constant-current regulation ensures that the PE test current doesn’t fall below the value required by VDE. In addition, the regulation is very fast, which results in short test times. The PE test has sufficient reserves for being able to perform tests from a distance of several meters, which is necessary especially at large machines. The tester has, of course, also a PE minimum current monitoring, which checks, whether the required test current is fallen below. |
| Feature | PE evaluation selectable between voltage drop or resistance | | According to the standards, the evaluation of the PE test is selectable. |
| Feature | electronic IR voltage adjustment | | The electronic constant-current regulation ensures that the IR test voltage doesn’t fall below the value required by VDE. In addition, the regulation is very fast, which results in short test times. |
| Feature | calibration solely via the software | | The complete calibration is performed via the software. It is not necessary to open the device. |
| Feature | actual-value storage for the results in the tester | | The tester can store test results inside the tester until they are read out by a PC program or by another control (e.g. PLC) at a later time. Available PC programs are PrintCom and NetCom. |
| Feature | set-up adjustments | | In the set-up of the tester you can configure the complete behavior of the tester and adapt it to your requirements. At the device itself, you can configure everything as desired, from language selection to printer control or interface configuration. No PC is required for the configuration. |
| Feature | PC-Software: PrintCom | | This software allows easy reading in of test results, storage in an EXCEL® file and comfortable printing of self-generated test programs. |
| Feature | PC-Software: NetCom | | With this software the tester can be remote-controlled completely. All test programs and test results are stored in a central ACCESS® database. The test results can be printed and statistically evaluated in many different ways. |

 | Safety Barriers Safety barriers serve to prevent access to test areas according to standards. The chains are supposed to preve....
more |
 | Black box According to VDE regulations, testing devices must be regularly submitted to functional tests. This guarantees....
more |
 | Test Covers - single Test covers serve for the protection of the operator and prevent that the test object is touched during the te....
more |
 | Foot switch The foot switch can be used for starting a test. Depending on the configuration of a tester, the foot switch m....
more |
 | Lamp Adapters Lamp adapters serve for contacting the lamp-holders in luminaires. At the connection leads of the lamp adaptor....
more |
 | Test Probes SCHLEICH offers a great variety of test probes for the PE test and for the insulation resistance test. The tes....
more |
 | Rolling Tables Rolling tables are ideally suited for transporting a tester or a combination of a tester and a test cover with....
more |
 | Warning Lamps Warning lamps serve to indicate, whether a test object is connected to voltage or not. ....
more |
 | GLP2-e/i Going future. The introdruction of the testing device GLP2 was revolutionary. On the basis of a modular concep....
more |
 | GLP3-2000 Our GLP3-2000 Windows® testers belong to our first-class range for testing a great variety of products. They a....
more |
 | Handheld This Handheld tester is remarkable for its integration of functions, higher power density and miniaturization.....
more |
 | NetCom Xi NetCom Xi is our answer to modern data management of test programs and test results. NetCom Xi is a Windows® s....
more |
 | PrintCom PrintCom is the easiest and most efficient solution for storing test results and printing test protocols. ....
more |
|