GLP1-e | Single- or combinationtester [PE + Iso + HV + Function]


   

GLP1-e

The GLP1-e L is an extremely compact testing device for testing the electrical safety and function of electronic products according to a great variety of national and international regulations. It is ideally suited for routine tests in series production. Fast, uncomplicated and reliable testing in accordance with ISO9001 with or without result documentation is essential. The GLP1-e L is available as single or combination tester.
 


Highlights

Product Features

universal testing device for electronic products and lamps | lamp tester

combination tester with manual procedure of the test methods (PE + ISO + CNT + function) 

2-line, 16-digit, well readable blue LCD

comfortable operation and adjustment

PE resistance test with 10A (30A) AC in 4-wire configuration / evaluation on resistance or voltage drop

insulation resistance test / evaluation on insulation resistance or current

lamp tester with switchover for protection class I / II

optional with high-voltage test incl. safety current limitation to 3mA | either 1500V AC constant or switchable via the protection class switch 1500V/4000V AC constants

short-circuit test before the functional test

continuity test with evaluation of the minimum and maximum contact resistance

secured functional test with current measurement and evaluation

functional test via integrable isolating transformer

functional test with up to 3 currents for products with up to 3 different current circuits

ideal for lamp testing

acoustic error message and optical signal at the device and via "signal lamps"

indication of the type of error in clear text

continuity test via measuring leads for testing connections

adjustment of the language and various other functions of the tester directly via the input keys (no PC necessary for the configuration)

connections for Emergency Stop, safety contact and warning lamp

RS232 for printer or remote control

remote-control mode / completely remote-controllable via RS232 interface

remote-control mode / completely remote-controllable via digital inputs and outputs

easy-to-operate menu for adjusting limit values, times, etc.

self-test via black box according to VDE

WINDOWS® software for remote control, for the administration of databases for test programs and test results and for printing-out test protocols

network (wired or wireless) with testing devices and a central PC with NetCom Xi

I/O interface and analog control inputs and actual value outputs

19" installation material

Product Description

With the necessary minimum of setting parameters, the GLP1-e L has been designed for standard test processes. If more complex test processes and more test methods are required, we are looking at testers from our GLP2 family.

The front panel of the tester has an earthed socket where you can connect the test object. Four additional 4mm safety laboratory sockets (L/N/PE1+PE1-Sense / parallel to the earthed socket) allow the connection of mains adaptors with banana plug. Laboratory measuring leads can be connected here, as well. In addition, a connection socket for the PE test probe is installed at the front panel. Two additional 4mm safety laboratory sockets (PE2+PE2-Sense / parallel to the connection socket) allow the connection of laboratory measuring leads. In order to ensure a precise measurement, the measurement is consistently performed in 4-wire configuration all the way to the PE test probe. Complicated balancing to the PE test are therefore not necessary. The PE test probe is also used for testing the insulation capability at electrical goods of protection class II. With the test probe, electrically conductive parts are tested for their insulation against the current-carrying leads (L+N). For an even more convenient operation, a test probe with integrated start switch is available.

A test process starts with the PE test and the insulation resistance test, which can take place at the same time. For this purpose, between the PE supply terminal and the test probe, the ground continuity is detected in 4-wire configuration. If various PE points are to be tested, the operator contacts the points one after the other. In order to obtain an optimum process speed, the PE test process can start itself immediately by touching the test object. After the safety tests have been completed, the testing device checks automatically, whether the resistance between L and N is too low. If there is no short circuit, the function test follows immediately. It can be done with our without evaluation of the current. All these advantages offer a very high test safety. With the monitoring functions that can be activated, it is possible, even for untrained personnel, to perform the tests safely and reliably. The integrated minicomputer allows functional operation and programming. The test parameters of the individual tests can be adapted to the testing task. The blackbox test, required by VDE, is integrated, as well.

Test Methods

Test
Data
PE resistance test
0 ... 0.7Ω / 10A AC electronic constant-current source / max. 12V

insulation resistance test
0 ... 30MΩ / 100 ... 1000V DC / max. 4mA

high-voltage test

1500VAC or 1500VAC/4000VAC | max. 3mA
short-circuit test
test before the functional test, whether the test object has no short-circuit
functional test / current consumption
0.001 ... 5A / 1-phase / 230V fixed voltage directly from the mains or via isolating transformer

Product Overview

PhotoDevices

PE

 

article number

401851

401868

ground-continuity test

10A

10A/25A

measuring range

0 ... 0.7Ω

0 ... 0.7Ω

resolution  

0.001Ω

0.001Ω

max. voltage 

<12V

<12V

test time0.1 ... 10s0.1 ... 10s

IR

 

article number

401852

insulation-resistance test

100 ... 1000V

measuring range

0.2 ... 30MΩ

resolution   

10KΩ / 100KΩ

max. current 

<3mA

test time 

0.1 ... 600s

PE + IR

 

article number

401865

4018113

4018105

4018112

ground-continuity test

10A

10A

10A/25A

10A/25A

measuring range

0 ... 0.7Ω

0 ... 0.7Ω

0 ... 0.7Ω

0 ... 0.7Ω

resolution

0.001Ω

0.001Ω

0.001Ω

0.001Ω

max. voltage 

<12V

<12V

<12V

<12V

test time

0.1 ... 10s

0.1 ... 10s

0.1 ... 10s

0.1 ... 10s

insulation-resistance test

100 ... 1000V

100 ... 2600V

100 ... 1000V

100 ... 2600V

measuring range

0.2 ... 30MΩ

0.2 ... 30MΩ

0.2 ... 30MΩ

0.2 ... 30MΩ

resolution   

10KΩ/100KΩ

10KΩ/100KΩ

10KΩ/100KΩ

10KΩ/100KΩ

max. current 

<3mA

<3mA

<3mA

<3mA

test time 

0.1 ... 600s

0.1 ... 600s

0.1 ... 600s

0.1 ... 600s

PE + IR + FCT

 

article number

40185015

40185020

ground-continuity test

10A

10A

insulation-resistance test

100 ... 1000V

100 ... 1000V

short-circuit test between L+N

functional test at mains voltage 

2A

5A

PE + IR + FCT + HV 1500V

 

article number

40185026

40185027

ground-continuity test

10A

10A

insulation-resistance test

100 ... 1000V

100 ... 1000V

short-circuit test between L+N

functional test at mains voltage 

2A

5A

high-voltage test AC

1500V

1500V

PE + IR + FCT + HV 1500V/4000V

article number

40185021

40185022

ground-continuity test

10A

10A

insulation-resistance test

100 ... 1000V

100 ... 1000V

short-circuit test between L+N

functional test at mains voltage 

2A

5A

high-voltage test AC

1500V/4000V

1500V/4000V

  At this device, a high-voltage test pistol is used as test probe.

Interfaces

RS232

PLC

PC

printer  

printer  

warning lamp  

result lamp 

foot switch

Analog Out

RS232 for remote control of the testing device via a PC

  • RS232 for printing test protocols (ASCII format) 
  • RS232 for remote control of the testing device via a PLC
  • digital inputs for connecting a foot switch, an external start switch or a control panel
  • digital inputs for remote control of the testing device via a PLC
  • digital outputs for the indication of the test result via a result lamp
  • digital outputs for the indication of the state of risk via a warning lamp
  • digital outputs for the indication of the condition of the device
  • analog output [optional]
  • For communicating with the electronic environment, the tester is equipped with a serial interface. It is possible to print or, alternatively, remote-control the tester via a PC with our software NetComXi or PrintCom. A test step generated in NetCom is transmitted to the tester, where it is performed and the result is returned to the PC. NetCom stores the result on the PC. This is the ultimate solution, because you have a test system, which documents and logs all test steps.

    In addition, it is possible to operate all testers of the following families in one network with a central PC: Handheld, GLP1 and GLP2. Test programs can be transmitted to the testers and the test results can be returned to the PC, where they are stored. The complete data exchange is controlled via our PC software NetComXi. For details, please refer to "NetComXi" or "PrintCom".

    A remote control via Agilent VEE® or LabVIEW® is possible without problems. For LabVIEW® a high-performance driver is available.

      remote control via Agilent VEE®

      remote control via LabVIEW®

     

    Technical Data

    Supply                                                                                          

    mains voltage

    230VAC +-10%

    frequency

    49Hz / 61Hz                        

    fuse protection

    10 Amp

    General Information

    language of the software

    German, English, Italian / selectable at the tester 

    programming

    free programming of all parameters directly at the tester

    remote control

    digital

    yes | belongs to the basic delivery extent

    RS232

    yes | belongs to the basic delivery extent
    analogyes - optional

    start test

    front switch, foot switch, start switch in the test probe, digital input

    safetykey switch for HV
    safety test pistols                      

    Emergency-Stop contact

    protection-cover safety contact for limit switches

    display

    2 * 16-line high-contrast display blue/white

    result storage

    up to 128 results / optional 1024 results

    enclosure

    solid and robust industrial aluminum enclosure

    dimensions236 * 320 * 178 mm (W*D*H)
    weight16kg
    colorside panels RAL7035 / top RAL 7035
    operating temperature10 degrees ... 50 degrees Celsius
    storing temperature-20 degrees ... 60 degrees Celsius
    calibration

    incl. calibration certificate

    Output Data | Functional Test

    voltage

    230V from the mains or via isolating transformer

    current

    max. 5A (2A)

    frequency of the voltage50Hz / 60Hz (depending on the mains) 50Hz / 60Hz (depending on the mains)

    General Information | Functional Test

    current measurement

    yes

    evaluation

    with GO/NO GO evaluation of the current

    voltage measurement

    no
    Imax  maximum current limit range0.01 ... 5 A (2A)
    resolution0.01A
    accuracy+- 2% of setting value  +- 0.01A
    Imin  minimum current limit range0.01 ... 5 A (2A)
    resolution0.01A
    accuracy+- 2% of setting value  +- 0.01A
    test time

    adjustable

    0 ... 10.0 s

    resolution

    0.1 s

    accuracy

    +- 0.1% of setting value  +0.05s

     

     High-Voltage Test

    Output Data                                                                                

    voltage

    1500V AC or 1500V/4000V

    current

    max. 3mA AC

    frequency of the voltage50Hz / 60Hz  (depending on the mains)

    General Information                                                                                

    test method

    true r.m.s. measurement

    evaluation

    with GO/NO GO evaluation of the current

    test type protection class IL+N against the PE of the test socket
    test type protection class IIL+N against the test probe
    test probe 1500Vtest probe for PE, IR and HV
    test probe 1500V / 4000Vtest pistol with integrated start pushbutton for PE, IR and HV
    fault signal

    optical and acoustical

    test time

    adjustable

    0 ... 10.0s

    resolution

    0.1s

    accuracy

    +- 0.1% of setting value + 0.05s

     

     Ground-Continuity Test

    Output Data                                                                                          

    voltage

    max. 12V AC

    current

    min. 10A AC 

    regulation

    automatic constant-current regulation           

    frequency of the voltage50Hz / 60Hz  (depending on the mains)

    Rmax (maximum PE resistance)                                                          

    range

    0.01 ... 0.7W

    resolution

    0.01W 

    accuracy

    +- 2% of measured value  +- 0.01W                        

    General Information                                                                                               

    test method

    4-wire resistance measurement / Kelvin measurement

    evaluation                                                          

    with GO/NO GO evaluation

    limit-value evaluation 

    max. resistance or max. voltage drop          

    test type

    test probe against the PE of the test object

    test probe

    light test probe with removable test prod

    up to the test probe in 4-wire configuration

    with integrated start switch (option)
    fault signal

    optical and acoustical

    test timeadjustable

    0 ... 10.0s

    resolution

    0.1s

    accuracy

    +- 0.1% of setting value + 0.05s

     

     Insulation Test

    Output Data                                                                                       

    voltage

    100V DC ... 1000V DC

    current

    max. 4mA DC

    regulation

    automatic constant-current regulation                  

    accuracy+- 10V

    setting step size

    10V

    Rmin (minimum IR resistance)                                                              

    range

    0.05 ... 30MW

    resolution

    10KW

    accuracy

    +- 2% of measured value +- 10KW                     

     

    Features

    Feature

    solid aluminum metal enclosure

    The tester has a solid industrial design. For industrial applications, instable plastic enclosures have major disadvantages. Especially in the rough day-to-day production, high-voltage testers must have a great stability and long-term safety.

    Feature

    automatic storage of the setting values in the tester

    After switching on the mains voltage, in order to avoid operating errors, the device boots with the parameters and the test program of the preceding test.

    Feature

    adjustment of all parameters via comfortable menu navigation

    The comfortable menus make sure that the operator can adjust all test parameters directly at the tester. An external PC for the configuration of the tester is not necessary!

    Feature

    electronic test time

    The electronic test time ensures that the test time remains the same for every tested product, which enables constant test results.

    FeatureAnzeige von Prüfparametern und Prüfergebnissen über LCD
    Über eine LCD kann der Bediener die Prüfung beobachten. Nach dem Test eines Prüfobjektes bleibt das Ergebnis auf der LCD sichtbar, damit sich der Bediener die Prüfergebnisse bequem ansehen kann. 

    Feature

    display of test steps and individual test results via LED lamps

    Various LED lamps (red, yellow, green) serve for indicating the status of the test step. Every test method has its own LED lamp.

    Feature

    test probe for PE test and insulation-resistance test

    The PE and the insulation to the enclosure of the test object are tested with one test probe. For this purpose, the enclosure of the test object is connected to the tester via a ground lead. This allows fast and safe testing.

    Feature

    electronic PE current regulation

    The electronic constant-current regulation ensures that the PE test current doesn’t fall below the value required by VDE. In addition, the regulation is very fast, which results in short test times. The PE test has sufficient reserves for being able to perform tests from a distance of several meters, which is necessary especially at large machines. The tester has, of course, also a PE minimum current monitoring, which checks, whether the required test current is fallen below.

    Feature

    PE evaluation selectable between voltage drop or resistance 

    According to the standards, the evaluation of the PE test is selectable.

    Feature

    electronic IR voltage adjustment 

    The electronic constant-current regulation ensures that the IR test voltage doesn’t fall below the value required by VDE. In addition, the regulation is very fast, which results in short test times.

    Feature

    calibration solely via the software

    The complete calibration is performed via the software. It is not necessary to open the device.

    Feature

    actual-value storage for the results in the tester

    The tester can store test results inside the tester until they are read out by a PC program or by another control (e.g. PLC) at a later time. Available PC programs are PrintCom and NetCom.

    Feature

    set-up adjustments

    In the set-up of the tester you can configure the complete behavior of the tester and adapt it to your requirements. At the device itself, you can configure everything as desired, from language selection to printer control or interface configuration. No PC is required for the configuration.

    FeaturePC-Software: PrintCom

    This software allows easy reading in of test results, storage in an EXCEL® file and comfortable printing of self-generated test programs.

    FeaturePC-Software: NetCom

    With this software the tester can be remote-controlled completely. All test programs and test results are stored in a central ACCESS® database. The test results can be printed and statistically evaluated in many different ways.

    Accessories

    Safety Barriers
    Safety barriers serve to prevent access to test areas according to standards. The chains are supposed to preve....
    more

    Black box
    According to VDE regulations, testing devices must be regularly submitted to functional tests. This guarantees....
    more

    Test Covers - single
    Test covers serve for the protection of the operator and prevent that the test object is touched during the te....
    more

    Foot switch
    The foot switch can be used for starting a test. Depending on the configuration of a tester, the foot switch m....
    more

    Adapters For Test Objects
    The adapter (the contacting) serves to connect the test object to the tester. The type of adapter depends on t....
    more

    Lamp Adapters
    Lamp adapters serve for contacting the lamp-holders in luminaires. At the connection leads of the lamp adaptor....
    more

    Test Probes
    SCHLEICH offers a great variety of test probes for the PE test and for the insulation resistance test. The tes....
    more

    Rolling Tables
    Rolling tables are ideally suited for transporting a tester or a combination of a tester and a test cover with....
    more

    Test Covers - special design
    Test covers serve for the protection of the operator and prevent that the test object is touched during the te....
    more

    Warning Lamps
    Warning lamps serve to indicate, whether a test object is connected to voltage or not. ....
    more



    Related products

    GLP2-e/i
    Going future. The introdruction of the testing device GLP2 was revolutionary. On the basis of a modular concep....
    more

    GLP3-2000
    Our GLP3-2000 Windows® testers belong to our first-class range for testing a great variety of products. They a....
    more

    Handheld
    This Handheld tester is remarkable for its integration of functions, higher power density and miniaturization.....
    more

    NetCom Xi
    NetCom Xi is our answer to modern data management of test programs and test results. NetCom Xi is a Windows® s....
    more

    PrintCom
    PrintCom is the easiest and most efficient solution for storing test results and printing test protocols. ....
    more

     

     

    eMail us    +49 (0) 2372/9498-0      Print Page    Recommend this Site    Add to the favorites Back To Top